{"id":"CVE-2025-31361","state":"PUBLISHED","title":"Dell ControlVault3 ControlVault WBDI Driver Broadcom Storage Adapter privilege escalation vulnerability","description":"A privilege escalation vulnerability exists in the ControlVault WBDI Driver WBIO_USH_ADD_RECORD functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to privilege escalation. An attacker can issue an api call to trigger this vulnerability.","publishedAt":"2025-11-17T22:54:06.711Z","updatedAt":"2026-02-26T16:56:52.104Z","severity":{"score":8.7,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:L","source":"talos"},"assigner":"talos","products":["Broadcom BCM5820X","Dell ControlVault3","Dell ControlVault3 Plus"],"affected":[{"vendor":"Broadcom","product":"BCM5820X","defaultStatus":"unaffected","versions":[{"version":"NA","status":"affected"}]},{"vendor":"Dell","product":"ControlVault3","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"5.15.14.19","versionType":"semver"}]},{"vendor":"Dell","product":"ControlVault3 Plus","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"6.2.36.47","versionType":"semver"}]}],"references":["https://www.dell.com/support/kbdoc/en-us/000326061/dsa-2025-228","https://talosintelligence.com/vulnerability_reports/TALOS-2025-2174","https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2174"],"weaknesses":["CWE-908"],"ingestedAt":"2026-10-29T20:08:55.257Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/31xxx/CVE-2025-31361.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-31361","state":"PUBLISHED","datePublished":"2025-11-17T22:54:06.711Z","dateUpdated":"2026-02-26T16:56:52.104Z","assignerShortName":"talos","assignerOrgId":"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b","dateReserved":"2025-04-15T14:39:55.683Z"},"containers":{"cna":{"title":"Dell ControlVault3 ControlVault WBDI Driver Broadcom Storage Adapter privilege escalation vulnerability","descriptions":[{"lang":"en","value":"A privilege escalation vulnerability exists in the ControlVault WBDI Driver WBIO_USH_ADD_RECORD functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to privilege escalation. An attacker can issue an api call to trigger this vulnerability."}],"affected":[{"vendor":"Broadcom","product":"BCM5820X","defaultStatus":"unaffected","versions":[{"version":"NA","status":"affected"}]},{"vendor":"Dell","product":"ControlVault3","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"5.15.14.19","versionType":"semver"}]},{"vendor":"Dell","product":"ControlVault3 Plus","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"6.2.36.47","versionType":"semver"}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000326061/dsa-2025-228"},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2025-2174"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"LOW","baseScore":8.7,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:L","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-908","description":"CWE-908 Use of Uninitialized Resource","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"talos","orgId":"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b","dateUpdated":"2025-11-17T22:55:44.335Z"},"credits":[{"lang":"en","type":"finder","value":"Discovered by Philippe Laulheret of Cisco Talos."}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2174"}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2025-11-17T23:05:39.573Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2025-31361","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2025-11-19T04:55:27.500052Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-02-26T16:56:52.104Z"}}]}}}