{"id":"CVE-2025-30280","state":"PUBLISHED","title":"A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (All versions < V10.18.","description":"A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (All versions < V10.18.5), Mendix Runtime V10.6 (All versions < V10.6.22), Mendix Runtime V8 (All versions < V8.18.35), Mendix Runtime V9 (All versions < V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application.","publishedAt":"2025-04-08T08:22:31.167Z","updatedAt":"2025-06-10T15:17:23.562Z","severity":{"score":6.9,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens Mendix Runtime V10","Siemens Mendix Runtime V10.12","Siemens Mendix Runtime V10.18","Siemens Mendix Runtime V10.6","Siemens Mendix Runtime V8","Siemens Mendix Runtime V9"],"affected":[{"vendor":"Siemens","product":"Mendix Runtime V10","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.21.0","versionType":"custom"}]},{"vendor":"Siemens","product":"Mendix Runtime V10.12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.12.16","versionType":"custom"}]},{"vendor":"Siemens","product":"Mendix Runtime V10.18","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.18.5","versionType":"custom"}]},{"vendor":"Siemens","product":"Mendix Runtime V10.6","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.6.22","versionType":"custom"}]},{"vendor":"Siemens","product":"Mendix Runtime V8","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.18.35","versionType":"custom"}]},{"vendor":"Siemens","product":"Mendix Runtime V9","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V9.24.34","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-874353.html"],"weaknesses":["CWE-204"],"ingestedAt":"2026-10-29T20:08:55.257Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/30xxx/CVE-2025-30280.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-30280","state":"PUBLISHED","datePublished":"2025-04-08T08:22:31.167Z","dateUpdated":"2025-06-10T15:17:23.562Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2025-03-20T11:01:33.481Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (All versions < V10.18.5), Mendix Runtime V10.6 (All versions < V10.6.22), Mendix Runtime V8 (All versions < V8.18.35), Mendix Runtime V9 (All versions < V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application."}],"affected":[{"vendor":"Siemens","product":"Mendix Runtime V10","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.21.0","versionType":"custom"}]},{"vendor":"Siemens","product":"Mendix Runtime V10.12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.12.16","versionType":"custom"}]},{"vendor":"Siemens","product":"Mendix Runtime V10.18","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.18.5","versionType":"custom"}]},{"vendor":"Siemens","product":"Mendix Runtime V10.6","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.6.22","versionType":"custom"}]},{"vendor":"Siemens","product":"Mendix Runtime V8","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.18.35","versionType":"custom"}]},{"vendor":"Siemens","product":"Mendix Runtime V9","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V9.24.34","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-874353.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":5.3,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","baseScore":6.9,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-204","lang":"en","description":"CWE-204: Observable Response Discrepancy","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2025-06-10T15:17:23.562Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-08T13:10:20.606472Z","id":"CVE-2025-30280","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-08T13:12:03.334Z"}}]}}}