{"id":"CVE-2025-2884","state":"PUBLISHED","title":"Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation","description":"TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0","publishedAt":"2025-06-10T17:29:19.463Z","updatedAt":"2026-10-15T01:01:59.300Z","severity":{"score":6.6,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H","source":"CISA-ADP"},"assigner":"certcc","products":["Trusted Computing Group TPM2.0"],"affected":[{"vendor":"Trusted Computing Group","product":"TPM2.0","versions":[{"version":"0","status":"affected","lessThan":"1.83","versionType":"custom"}]}],"references":["https://trustedcomputinggroup.org/about/security/","https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf","https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf","https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1","https://www.cve.org/CVERecord?id=CVE-2025-49133","https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html","https://www.kb.cert.org/vuls/id/282450","https://cert-portal.siemens.com/productcert/html/ssa-628843.html"],"weaknesses":["CWE-125"],"ingestedAt":"2026-10-29T20:08:55.257Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/2xxx/CVE-2025-2884.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-2884","state":"PUBLISHED","datePublished":"2025-06-10T17:29:19.463Z","dateUpdated":"2026-10-15T01:01:59.300Z","assignerShortName":"certcc","assignerOrgId":"37e5125f-f79b-445b-8fad-9564f167944b","dateReserved":"2025-03-27T21:01:41.908Z"},"containers":{"cna":{"title":"Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation","descriptions":[{"lang":"en","value":"TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0"}],"affected":[{"vendor":"Trusted Computing Group","product":"TPM2.0","versions":[{"version":"0","status":"affected","lessThan":"1.83","versionType":"custom"}]}],"references":[{"url":"https://trustedcomputinggroup.org/about/security/"},{"url":"https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf","name":"TPM2.0 Errata"},{"url":"https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf","name":"Vendor Advisory"},{"url":"https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1","name":"Vendor Patch"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-49133","name":"Related CVE"}],"metrics":[{"other":{"type":"ssvcV1_0_1","content":{"id":"CVE-2025-2884","selections":[{"namespace":"ssvc","version":"1.0.0","values":["none"],"name":"Exploitation"},{"namespace":"ssvc","version":"2.0.0","values":["no"],"name":"Automatable"},{"namespace":"ssvc","version":"1.0.0","values":["partial"],"name":"Technical Impact"},{"namespace":"ssvc","version":"1.0.0","values":["medium"],"name":"Mission & Well-being"}],"timestamp":"2025-06-13T17:22:30.584Z"}}}],"problemTypes":[{"descriptions":[{"lang":"en","description":"CWE-125 Out-of-bounds Read"}]}],"providerMetadata":{"shortName":"certcc","orgId":"37e5125f-f79b-445b-8fad-9564f167944b","dateUpdated":"2025-06-13T18:22:21.856Z"},"source":{"discovery":"INTERNAL"},"x_generator":{"engine":"VINCE 3.0.20","env":"prod","origin":"https://cveawg.mitre.org/api/cve/CVE-2025-2884"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html"},{"url":"https://www.kb.cert.org/vuls/id/282450"}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2025-06-10T19:02:29.811Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":6.6,"attackVector":"LOCAL","baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H","integrityImpact":"NONE","userInteraction":"REQUIRED","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"LOW","confidentialityImpact":"HIGH"}},{"other":{"type":"ssvc","content":{"timestamp":"2025-06-13T01:41:10.489446Z","id":"CVE-2025-2884","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-125","type":"CWE","lang":"en","description":"CWE-125 Out-of-bounds Read"}]}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-06-13T01:46:13.802Z"}},{"affected":[{"vendor":"Siemens","product":"SIMATIC CN 4100","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC Field PG M5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC Field PG M6","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V26.01.14","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC BX-32A","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V29.01.09","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC BX-39A","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V29.01.09","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC BX-56A","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V32.01.09","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC BX-59A","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V32.01.09","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC MD-57A","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V30.01.10","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC PX-32A","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V29.01.09","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC PX-39A","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V29.01.09","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC PX-39A PRO","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V29.01.09","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC RW-528A","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V34.01.02","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC RW-548A","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V34.01.02","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC227E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC277E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC427E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V21.01.20","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC477E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V21.01.20","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC477E PRO","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V21.01.20","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC627E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V25.02.16","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC647E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V25.02.16","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC677E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V25.02.16","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC IPC847E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V25.02.16","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC ITP1000","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS IPC427E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V21.01.20","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-628843.html"}],"providerMetadata":{"shortName":"siemens-SADP","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","dateUpdated":"2026-10-15T01:01:59.300Z"},"x_adpType":"supplier"}]}}}