{"id":"CVE-2025-27769","state":"PUBLISHED","title":"A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affecte","description":"A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.","publishedAt":"2026-03-10T16:07:43.641Z","updatedAt":"2026-03-10T16:41:10.032Z","severity":{"score":2.4,"label":"Low","version":"4.0","vector":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens Heliox Flex 180 kW EV Charging Station","Siemens Heliox Mobile DC 40 kW EV Charging Station"],"affected":[{"vendor":"Siemens","product":"Heliox Flex 180 kW EV Charging Station","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"F4.11.1","versionType":"custom"}]},{"vendor":"Siemens","product":"Heliox Mobile DC 40 kW EV Charging Station","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"L4.10.1","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-126399.html"],"weaknesses":["CWE-923"],"ingestedAt":"2026-10-29T20:08:47.682Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/27xxx/CVE-2025-27769.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-27769","state":"PUBLISHED","datePublished":"2026-03-10T16:07:43.641Z","dateUpdated":"2026-03-10T16:41:10.032Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2025-03-06T16:53:49.577Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable."}],"affected":[{"vendor":"Siemens","product":"Heliox Flex 180 kW EV Charging Station","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"F4.11.1","versionType":"custom"}]},{"vendor":"Siemens","product":"Heliox Mobile DC 40 kW EV Charging Station","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"L4.10.1","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-126399.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N","baseScore":2.6,"baseSeverity":"LOW"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N","baseScore":2.4,"baseSeverity":"LOW"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-923","lang":"en","description":"CWE-923: Improper Restriction of Communication Channel to Intended Endpoints","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2026-03-10T16:07:43.641Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2025-27769","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2026-03-10T16:33:20.023387Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-03-10T16:41:10.032Z"}}]}}}