{"id":"CVE-2025-27398","state":"PUBLISHED","title":"A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly neutralize special characters when interpreting","description":"A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly neutralize special characters when interpreting user controlled log paths.\r\nThis could allow an authenticated highly-privileged remote attacker to execute a limited set of binaries that are already present on the filesystem.","publishedAt":"2025-03-11T09:48:30.045Z","updatedAt":"2025-03-11T13:30:28.112Z","severity":{"score":2.1,"label":"Low","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens SCALANCE LPE9403"],"affected":[{"vendor":"Siemens","product":"SCALANCE LPE9403","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.0","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-075201.html"],"weaknesses":["CWE-78"],"ingestedAt":"2026-10-29T20:08:47.682Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/27xxx/CVE-2025-27398.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-27398","state":"PUBLISHED","datePublished":"2025-03-11T09:48:30.045Z","dateUpdated":"2025-03-11T13:30:28.112Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2025-02-24T10:03:33.208Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly neutralize special characters when interpreting user controlled log paths.\r\nThis could allow an authenticated highly-privileged remote attacker to execute a limited set of binaries that are already present on the filesystem."}],"affected":[{"vendor":"Siemens","product":"SCALANCE LPE9403","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.0","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-075201.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C","baseScore":2.7,"baseSeverity":"LOW"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N","baseScore":2.1,"baseSeverity":"LOW"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","lang":"en","description":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2025-03-11T09:48:30.045Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-03-11T13:29:17.137806Z","id":"CVE-2025-27398","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-03-11T13:30:28.112Z"}}]}}}