{"id":"CVE-2025-27262","state":"PUBLISHED","title":"Ericsson Indoor Connect 8855 -  Improper Neutralization of Special Elements used in an OS Command Vulnerability","description":"Ericsson Indoor Connect 8855 contains a command injection vulnerability which if exploited can result in an escalation of privileges.","publishedAt":"2025-09-25T14:43:29.803Z","updatedAt":"2025-09-30T12:13:16.746Z","severity":{"score":8.5,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"ERIC"},"assigner":"ERIC","products":["Ericsson Indoor Connect 8855"],"affected":[{"vendor":"Ericsson","product":"Indoor Connect 8855","defaultStatus":"affected","versions":[{"version":"0","status":"affected","lessThan":"2025.Q2","changes":[{"at":"2025.Q2","status":"unaffected"}],"versionType":"Indoor Connect 8855"}]}],"references":["https://www.ericsson.com/en/about-us/security/psirt/e2025-09-25"],"weaknesses":["CWE-78"],"ingestedAt":"2026-10-29T20:08:47.682Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/27xxx/CVE-2025-27262.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-27262","state":"PUBLISHED","datePublished":"2025-09-25T14:43:29.803Z","dateUpdated":"2025-09-30T12:13:16.746Z","assignerShortName":"ERIC","assignerOrgId":"85b1779b-6ecd-4f52-bcc5-73eac4659dcf","dateReserved":"2025-02-21T08:58:20.367Z"},"containers":{"cna":{"title":"Ericsson Indoor Connect 8855 -  Improper Neutralization of Special Elements used in an OS Command Vulnerability","descriptions":[{"lang":"en","value":"Ericsson Indoor Connect 8855 contains a command injection vulnerability which if exploited can result in an escalation of privileges."}],"affected":[{"vendor":"Ericsson","product":"Indoor Connect 8855","defaultStatus":"affected","versions":[{"version":"0","status":"affected","lessThan":"2025.Q2","changes":[{"at":"2025.Q2","status":"unaffected"}],"versionType":"Indoor Connect 8855"}]}],"references":[{"url":"https://www.ericsson.com/en/about-us/security/psirt/e2025-09-25"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.5,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"ERIC","orgId":"85b1779b-6ecd-4f52-bcc5-73eac4659dcf","dateUpdated":"2025-09-30T12:13:16.746Z"},"credits":[{"lang":"en","type":"finder","value":"Telstra"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-09-25T15:18:14.273331Z","id":"CVE-2025-27262","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-09-25T15:27:05.382Z"}}]}}}