{"id":"CVE-2025-25267","state":"PUBLISHED","title":"A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected ap","description":"A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict the scope of files accessible to the simulation model. This could allow an unauthorized attacker to compromise the confidentiality of the system.","publishedAt":"2025-03-11T09:48:20.909Z","updatedAt":"2025-03-11T14:20:34.812Z","severity":{"score":6.9,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens Tecnomatix Plant Simulation V2302","Siemens Tecnomatix Plant Simulation V2404"],"affected":[{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2302.0021","versionType":"custom"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2404","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2404.0010","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-507653.html"],"weaknesses":["CWE-552"],"ingestedAt":"2026-10-29T20:08:47.682Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/25xxx/CVE-2025-25267.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-25267","state":"PUBLISHED","datePublished":"2025-03-11T09:48:20.909Z","dateUpdated":"2025-03-11T14:20:34.812Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2025-02-06T12:40:49.316Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict the scope of files accessible to the simulation model. This could allow an unauthorized attacker to compromise the confidentiality of the system."}],"affected":[{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2302.0021","versionType":"custom"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2404","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2404.0010","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-507653.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":6.2,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","baseScore":6.9,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-552","lang":"en","description":"CWE-552: Files or Directories Accessible to External Parties","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2025-03-11T09:48:20.909Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-03-11T14:20:14.270383Z","id":"CVE-2025-25267","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-03-11T14:20:34.812Z"}}]}}}