{"id":"CVE-2025-24349","state":"PUBLISHED","title":"A vulnerability in the “Network Interfaces” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to delete the configuration of p","description":"A vulnerability in the “Network Interfaces” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to delete the configuration of physical network interfaces via a crafted HTTP request.","publishedAt":"2025-04-30T11:44:33.547Z","updatedAt":"2025-04-30T14:30:33.942Z","severity":{"score":7.1,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H","source":"bosch"},"assigner":"bosch","products":["Bosch Rexroth AG ctrlX OS - Device Admin"],"affected":[{"vendor":"Bosch Rexroth AG","product":"ctrlX OS - Device Admin","versions":[{"version":"1.12.0","status":"affected","lessThanOrEqual":"1.12.9","versionType":"custom"},{"version":"1.20.0","status":"affected","lessThanOrEqual":"1.20.7","versionType":"custom"},{"version":"2.6.0","status":"affected","lessThanOrEqual":"2.6.8","versionType":"custom"}]}],"references":["https://psirt.bosch.com/security-advisories/BOSCH-SA-640452.html"],"weaknesses":["CWE-183"],"ingestedAt":"2026-10-29T20:08:47.682Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/24xxx/CVE-2025-24349.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-24349","state":"PUBLISHED","datePublished":"2025-04-30T11:44:33.547Z","dateUpdated":"2025-04-30T14:30:33.942Z","assignerShortName":"bosch","assignerOrgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","dateReserved":"2025-01-20T15:09:10.534Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability in the “Network Interfaces” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to delete the configuration of physical network interfaces via a crafted HTTP request."}],"affected":[{"vendor":"Bosch Rexroth AG","product":"ctrlX OS - Device Admin","versions":[{"version":"1.12.0","status":"affected","lessThanOrEqual":"1.12.9","versionType":"custom"},{"version":"1.20.0","status":"affected","lessThanOrEqual":"1.20.7","versionType":"custom"},{"version":"2.6.0","status":"affected","lessThanOrEqual":"2.6.8","versionType":"custom"}]}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-640452.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-640452.html","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"HIGH","baseScore":7.1,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-183","lang":"en-US","description":"CWE-183 Permissive List of Allowed Inputs"}]}],"providerMetadata":{"shortName":"bosch","orgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","dateUpdated":"2025-04-30T11:44:33.547Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-30T14:30:15.140761Z","id":"CVE-2025-24349","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-30T14:30:33.942Z"}}]}}}