{"id":"CVE-2025-24341","state":"PUBLISHED","title":"A vulnerability in the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to induce a Denial-of-Service (DoS) condition on the device via multiple ","description":"A vulnerability in the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to induce a Denial-of-Service (DoS) condition on the device via multiple crafted HTTP requests. In the worst case, a full power cycle is needed to regain control of the device.","publishedAt":"2025-04-30T11:14:47.046Z","updatedAt":"2025-04-30T15:11:57.073Z","severity":{"score":6.5,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","source":"bosch"},"assigner":"bosch","products":["Bosch Rexroth AG ctrlX OS - Device Admin"],"affected":[{"vendor":"Bosch Rexroth AG","product":"ctrlX OS - Device Admin","versions":[{"version":"1.12.0","status":"affected","lessThanOrEqual":"1.12.9","versionType":"custom"},{"version":"1.20.0","status":"affected","lessThanOrEqual":"1.20.7","versionType":"custom"},{"version":"2.6.0","status":"affected","lessThanOrEqual":"2.6.8","versionType":"custom"}]}],"references":["https://psirt.bosch.com/security-advisories/BOSCH-SA-640452.html"],"weaknesses":["CWE-770"],"ingestedAt":"2026-10-29T20:08:47.682Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/24xxx/CVE-2025-24341.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-24341","state":"PUBLISHED","datePublished":"2025-04-30T11:14:47.046Z","dateUpdated":"2025-04-30T15:11:57.073Z","assignerShortName":"bosch","assignerOrgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","dateReserved":"2025-01-20T15:09:10.532Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability in the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to induce a Denial-of-Service (DoS) condition on the device via multiple crafted HTTP requests. In the worst case, a full power cycle is needed to regain control of the device."}],"affected":[{"vendor":"Bosch Rexroth AG","product":"ctrlX OS - Device Admin","versions":[{"version":"1.12.0","status":"affected","lessThanOrEqual":"1.12.9","versionType":"custom"},{"version":"1.20.0","status":"affected","lessThanOrEqual":"1.20.7","versionType":"custom"},{"version":"2.6.0","status":"affected","lessThanOrEqual":"2.6.8","versionType":"custom"}]}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-640452.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-640452.html","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-770","lang":"en-US","description":"CWE-770 Allocation of Resources Without Limits or Throttling"}]}],"providerMetadata":{"shortName":"bosch","orgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","dateUpdated":"2025-04-30T11:14:47.046Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-30T15:09:35.775128Z","id":"CVE-2025-24341","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-30T15:11:57.073Z"}}]}}}