{"id":"CVE-2025-23364","state":"PUBLISHED","title":"A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application improperly validates code signing certificates.\r","description":"A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application improperly validates code signing certificates.\r\nThis could allow an attacker to bypass the check and exceute arbitrary code during installations.","publishedAt":"2025-07-08T10:34:28.904Z","updatedAt":"2025-07-08T16:11:54.563Z","severity":{"score":6.9,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens TIA Administrator"],"affected":[{"vendor":"Siemens","product":"TIA Administrator","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.6","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-573669.html"],"weaknesses":["CWE-347"],"ingestedAt":"2026-10-29T20:08:39.238Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/23xxx/CVE-2025-23364.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-23364","state":"PUBLISHED","datePublished":"2025-07-08T10:34:28.904Z","dateUpdated":"2025-07-08T16:11:54.563Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2025-01-14T14:16:18.187Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application improperly validates code signing certificates.\r\nThis could allow an attacker to bypass the check and exceute arbitrary code during installations."}],"affected":[{"vendor":"Siemens","product":"TIA Administrator","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.6","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-573669.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C","baseScore":6.2,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","baseScore":6.9,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-347","lang":"en","description":"CWE-347: Improper Verification of Cryptographic Signature","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2025-07-08T10:34:28.904Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-07-08T14:26:22.894853Z","id":"CVE-2025-23364","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-07-08T16:11:54.563Z"}}]}}}