{"id":"CVE-2025-14097","state":"PUBLISHED","title":"Remote Code Execution Vulnerability in Radiometer Products","description":"A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means.  The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 & CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\nRequired Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution:\nCustomers should ensure the following:\n•  The network is secure, and access follows best practices.\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                     \nExploit Status:\n\n\nResearchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.","publishedAt":"2025-12-17T12:36:03.779Z","updatedAt":"2025-12-17T14:41:13.252Z","severity":{"score":7.2,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","source":"Radiometer"},"assigner":"Radiometer","products":["Radiometer Medical Aps ABL90 FLEX and ABL90 FLEX PLUS Analyzers","Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX Analyzers","Radiometer Medical Aps AQT90 FLEX Analyzers"],"affected":[{"vendor":"Radiometer Medical Aps","product":"ABL90 FLEX and ABL90 FLEX PLUS Analyzers","defaultStatus":"unaffected","versions":[{"version":"Application software versions < 3.5MR11 with Windows 7, Windows XP operating systems","status":"affected","versionType":"ABL90 DMS (Data Management system)"},{"version":"Application software versions >= 3.5MR11 with Windows 10 operating system","status":"unaffected","versionType":"ABL90 DMS (Data Management system)"}]},{"vendor":"Radiometer Medical Aps","product":"ABL800 BASIC and ABL800 FLEX Analyzers","defaultStatus":"unaffected","versions":[{"version":"Application software versions < 6.20MR2 with Windows 7, Windows XP operating systems","status":"affected","versionType":"ABL800 DMS(Data Management System)"},{"version":"Application software versions >= 6.20MR2 with Windows 10 operating system","status":"unaffected","versionType":"ABL800 DMS(Data Management System)"}]},{"vendor":"Radiometer Medical Aps","product":"AQT90 FLEX Analyzers","defaultStatus":"unaffected","versions":[{"version":"Application software versions <= 8.13 MR2 with Windows 7, Windows XP operating systems","status":"affected","versionType":"AQT90 DMS (Data Management System)"},{"version":"Application software versions >= 8.13 MR2 with Windows 10 operating system","status":"unaffected","versionType":"AQT90 DMS (Data Management System)"}]}],"references":["https://www.radiometer.com/myradiometer"],"weaknesses":["CWE-287"],"ingestedAt":"2026-10-29T20:08:31.050Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/14xxx/CVE-2025-14097.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-14097","state":"PUBLISHED","datePublished":"2025-12-17T12:36:03.779Z","dateUpdated":"2025-12-17T14:41:13.252Z","assignerShortName":"Radiometer","assignerOrgId":"46b595e9-1acc-41cb-9398-adaf98d37a9b","dateReserved":"2025-12-05T10:50:03.683Z"},"containers":{"cna":{"title":"Remote Code Execution Vulnerability in Radiometer Products","descriptions":[{"lang":"en","value":"A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means.  The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 & CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\nRequired Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution:\nCustomers should ensure the following:\n•  The network is secure, and access follows best practices.\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                     \nExploit Status:\n\n\nResearchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication."}],"affected":[{"vendor":"Radiometer Medical Aps","product":"ABL90 FLEX and ABL90 FLEX PLUS Analyzers","defaultStatus":"unaffected","versions":[{"version":"Application software versions < 3.5MR11 with Windows 7, Windows XP operating systems","status":"affected","versionType":"ABL90 DMS (Data Management system)"},{"version":"Application software versions >= 3.5MR11 with Windows 10 operating system","status":"unaffected","versionType":"ABL90 DMS (Data Management system)"}]},{"vendor":"Radiometer Medical Aps","product":"ABL800 BASIC and ABL800 FLEX Analyzers","defaultStatus":"unaffected","versions":[{"version":"Application software versions < 6.20MR2 with Windows 7, Windows XP operating systems","status":"affected","versionType":"ABL800 DMS(Data Management System)"},{"version":"Application software versions >= 6.20MR2 with Windows 10 operating system","status":"unaffected","versionType":"ABL800 DMS(Data Management System)"}]},{"vendor":"Radiometer Medical Aps","product":"AQT90 FLEX Analyzers","defaultStatus":"unaffected","versions":[{"version":"Application software versions <= 8.13 MR2 with Windows 7, Windows XP operating systems","status":"affected","versionType":"AQT90 DMS (Data Management System)"},{"version":"Application software versions >= 8.13 MR2 with Windows 10 operating system","status":"unaffected","versionType":"AQT90 DMS (Data Management System)"}]}],"references":[{"url":"https://www.radiometer.com/myradiometer"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-287","description":"CWE-287: Improper Authentication","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Radiometer","orgId":"46b595e9-1acc-41cb-9398-adaf98d37a9b","dateUpdated":"2025-12-17T13:14:55.334Z"},"configurations":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Affected application software version is in use AND Remote support feature is enabled in the Analyzer.\n\n<br>"}],"value":"Affected application software version is in use AND Remote support feature is enabled in the Analyzer."}],"credits":[{"lang":"en","type":"reporter","value":"Florian Hauser and Fabian Weber from CODE WHITE GmbH"}],"datePublic":"2025-12-17T12:35:00.000Z","exploits":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.\n\n<br>"}],"value":"Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication."}],"impacts":[{"capecId":"CAPEC-555","descriptions":[{"lang":"en","value":"CAPEC-555: Remote Services with Stolen Credentials"}]},{"capecId":"CAPEC-653","descriptions":[{"lang":"en","value":"CAPEC-653: Use of Known Operating System Credentials"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Customers should ensure the following:<br>•  The network is secure, and access follows best practices.<br>Local Radiometer representatives will contact all affected customers to discuss a permanent solution.\n\n\n\n<br>"}],"value":"Customers should ensure the following:\n•  The network is secure, and access follows best practices.\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution."}],"source":{"discovery":"EXTERNAL"},"timeline":[{"lang":"en","time":"2025-12-17T12:35:00.000Z","value":"CVE Published"}],"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"If the network is not considered secure, please remove the analyzer from the network."}],"value":"If the network is not considered secure, please remove the analyzer from the network."}],"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-12-17T14:40:30.048229Z","id":"CVE-2025-14097","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-12-17T14:41:13.252Z"}}]}}}