{"id":"CVE-2025-13036","state":"PUBLISHED","title":"Rockwell Automation FactoryTalk Historian Site Edition - Authentication Bypass","description":"An authentication\nbypass security issue exists within FactoryTalk Historian Site Edition. By\ncontinually sending requests to the login endpoint, an attacker may obtain a\nvalid authentication token.","publishedAt":"2026-06-16T13:50:11.944Z","updatedAt":"2026-06-16T15:26:21.599Z","severity":{"score":9.2,"label":"Critical","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","source":"Rockwell"},"assigner":"Rockwell","products":["Rockwell Automation FactoryTalk Historian SE"],"affected":[{"vendor":"Rockwell Automation","product":"FactoryTalk Historian SE","defaultStatus":"unaffected","versions":[{"version":"v11","status":"affected"}]}],"references":["https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html"],"weaknesses":["CWE-362"],"ingestedAt":"2026-10-29T20:08:31.050Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/13xxx/CVE-2025-13036.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-13036","state":"PUBLISHED","datePublished":"2026-06-16T13:50:11.944Z","dateUpdated":"2026-06-16T15:26:21.599Z","assignerShortName":"Rockwell","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","dateReserved":"2025-11-11T17:55:24.504Z"},"containers":{"cna":{"title":"Rockwell Automation FactoryTalk Historian Site Edition - Authentication Bypass","descriptions":[{"lang":"en","value":"An authentication\nbypass security issue exists within FactoryTalk Historian Site Edition. By\ncontinually sending requests to the login endpoint, an attacker may obtain a\nvalid authentication token."}],"affected":[{"vendor":"Rockwell Automation","product":"FactoryTalk Historian SE","defaultStatus":"unaffected","versions":[{"version":"v11","status":"affected"}]}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"LOW","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"CRITICAL","baseScore":9.2,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-362","lang":"en","description":"CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')","type":"CWE"}]}],"providerMetadata":{"shortName":"Rockwell","orgId":"b73dd486-f505-4403-b634-40b078b177f0","dateUpdated":"2026-06-16T13:50:11.944Z"},"datePublic":"2026-06-16T13:44:00.000Z","solutions":[{"lang":"en","value":"Upgrade to v12.00.00 and later","supportingMedia":[{"type":"text/html","base64":false,"value":"Upgrade to v12.00.00 and later<div><br></div>"}]}],"source":{"advisory":"SD1773","discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 1.0.2"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-06-16T15:26:12.135366Z","id":"CVE-2025-13036","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-06-16T15:26:21.599Z"}}]}}}