{"id":"CVE-2025-11567","state":"PUBLISHED","title":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.","description":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.","publishedAt":"2025-11-12T13:27:56.004Z","updatedAt":"2025-11-12T18:50:03.699Z","severity":{"score":7.3,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"schneider"},"assigner":"schneider","products":["Schneider Electric PowerChute™ Serial Shutdown"],"affected":[{"vendor":"Schneider Electric","product":"PowerChute™ Serial Shutdown","defaultStatus":"unaffected","versions":[{"version":"Versions v1.3 and prior","status":"affected","versionType":"custom"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-315-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-315-01.pdf"],"weaknesses":["CWE-276"],"ingestedAt":"2026-10-29T20:08:31.050Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/11xxx/CVE-2025-11567.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-11567","state":"PUBLISHED","datePublished":"2025-11-12T13:27:56.004Z","dateUpdated":"2025-11-12T18:50:03.699Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2025-10-09T15:17:30.858Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured."}],"affected":[{"vendor":"Schneider Electric","product":"PowerChute™ Serial Shutdown","defaultStatus":"unaffected","versions":[{"version":"Versions v1.3 and prior","status":"affected","versionType":"custom"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-315-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-315-01.pdf"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"LOCAL","baseScore":7.3,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-276","description":"CWE-276 Incorrect Default Permissions","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2025-11-12T18:50:03.699Z"},"datePublic":"2025-11-11T07:00:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-11-12T14:03:16.647582Z","id":"CVE-2025-11567","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-11-12T14:04:25.508Z"}}]}}}