{"id":"CVE-2025-10460","state":"PUBLISHED","title":"Unsanitized parameter input leading to SQL Injection vulnerability","description":"A SQL Injection vulnerability on an endpoint in BEIMS Contractor Web, a legacy product that is no longer maintained or patched by the vendor, allows an unauthorised user to retrieve sensitive database contents via unsanitized parameter input. This vulnerability occurs due to improper input validation on /BEIMSWeb/contractor.asp endpoint and successful exploitation requires a contractor.asp endpoint open to the internet. This vulnerability allows attackers to execute arbitrary SQL commands, compromising the confidentiality, integrity and potentially the availability of the database. \n\n\n\n\n\nVersion 5.7.139\n\n has been confirmed as vulnerable. Other versions have not been confirmed by the vendor and users should assume that all versions of BEIMS Contractor Web may be impacted until further guidance is provided by the vendor.","publishedAt":"2025-11-17T02:48:25.684Z","updatedAt":"2025-11-17T16:42:22.769Z","severity":{"score":9.4,"label":"Critical","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:H/SI:L/SA:N","source":"MON-CSIRT"},"assigner":"MON-CSIRT","products":["BEIMS Contractor Web"],"affected":[{"vendor":"BEIMS","product":"Contractor Web","defaultStatus":"affected","versions":[{"version":"5.7","status":"affected"}]}],"references":["https://help.fmiworks.com/knowledge/beims-web","https://help.fmiworks.com/knowledge/contractor-web-operational-requirements"],"weaknesses":["CWE-20"],"ingestedAt":"2026-10-29T20:08:20.985Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/10xxx/CVE-2025-10460.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-10460","state":"PUBLISHED","datePublished":"2025-11-17T02:48:25.684Z","dateUpdated":"2025-11-17T16:42:22.769Z","assignerShortName":"MON-CSIRT","assignerOrgId":"9c1820ae-fb77-4810-a8aa-ca46e7474d2f","dateReserved":"2025-09-15T05:46:32.298Z"},"containers":{"cna":{"title":"Unsanitized parameter input leading to SQL Injection vulnerability","descriptions":[{"lang":"en","value":"A SQL Injection vulnerability on an endpoint in BEIMS Contractor Web, a legacy product that is no longer maintained or patched by the vendor, allows an unauthorised user to retrieve sensitive database contents via unsanitized parameter input. This vulnerability occurs due to improper input validation on /BEIMSWeb/contractor.asp endpoint and successful exploitation requires a contractor.asp endpoint open to the internet. This vulnerability allows attackers to execute arbitrary SQL commands, compromising the confidentiality, integrity and potentially the availability of the database. \n\n\n\n\n\nVersion 5.7.139\n\n has been confirmed as vulnerable. Other versions have not been confirmed by the vendor and users should assume that all versions of BEIMS Contractor Web may be impacted until further guidance is provided by the vendor."}],"affected":[{"vendor":"BEIMS","product":"Contractor Web","defaultStatus":"affected","versions":[{"version":"5.7","status":"affected"}]}],"references":[{"url":"https://help.fmiworks.com/knowledge/beims-web"},{"url":"https://help.fmiworks.com/knowledge/contractor-web-operational-requirements"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"NETWORK","baseScore":9.4,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"LOW","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:H/SI:L/SA:N","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"CWE-20 Improper Input Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"MON-CSIRT","orgId":"9c1820ae-fb77-4810-a8aa-ca46e7474d2f","dateUpdated":"2025-11-17T02:48:25.684Z"},"credits":[{"lang":"en","type":"reporter","value":"Nicholas Page"}],"impacts":[{"capecId":"CAPEC-66","descriptions":[{"lang":"en","value":"CAPEC-66 SQL Injection"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">Users are advised to mitigate risk by restricting access to the affected endpoint or upgrading to a supported alternative. </span>\n\n<br>"}],"value":"Users are advised to mitigate risk by restricting access to the affected endpoint or upgrading to a supported alternative."}],"source":{"discovery":"INTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Vendor recommendations:<br><ul><li>Restrict access to your private intranet only</li><li>Implement a Web Application Firewall (WAF) to block malicious files</li><li>Consider using File Server Resource Manager with IIS to monitor file activity at the OS level</li></ul>"}],"value":"Vendor recommendations:\n  *  Restrict access to your private intranet only\n  *  Implement a Web Application Firewall (WAF) to block malicious files\n  *  Consider using File Server Resource Manager with IIS to monitor file activity at the OS level"}],"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-11-17T16:42:03.168458Z","id":"CVE-2025-10460","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-11-17T16:42:22.769Z"}}]}}}