{"id":"CVE-2025-0694","state":"PUBLISHED","title":"CODESYS Control V3 removable media path traversal","description":"Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access.","publishedAt":"2025-03-18T11:04:06.167Z","updatedAt":"2025-03-18T13:09:54.473Z","severity":{"score":6.6,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"CERTVDE"},"assigner":"CERTVDE","products":["CODESYS CODESYS Control for BeagleBone SL","CODESYS CODESYS Control for emPC-A/iMX6 SL","CODESYS CODESYS Control for IOT2000 SL","CODESYS CODESYS Control for Linux ARM SL","CODESYS CODESYS Control for Linux SL","CODESYS CODESYS Control for PFC100 SL","CODESYS CODESYS Control for PFC200 SL","CODESYS CODESYS Control for PLCnext SL","CODESYS CODESYS Control for Raspberry Pi SL","CODESYS CODESYS Control for WAGO Touch Panels 600 SL","CODESYS CODESYS Control RTE (for Beckhoff CX) SL","CODESYS CODESYS Control RTE (SL)","CODESYS CODESYS Control Win (SL)","CODESYS CODESYS Runtime Toolkit","CODESYS CODESYS Virtual Control SL"],"affected":[{"vendor":"CODESYS","product":"CODESYS Control for BeagleBone SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for emPC-A/iMX6 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for IOT2000 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux ARM SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC100 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC200 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PLCnext SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Raspberry Pi SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for WAGO Touch Panels 600 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (for Beckhoff CX) SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"3.5.21.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (SL)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"3.5.21.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control Win (SL)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"3.5.21.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Runtime Toolkit","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"3.5.21.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Virtual Control SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]}],"references":["https://cert.vde.com/en/advisories/VDE-2025-015"],"weaknesses":["CWE-22"],"ingestedAt":"2026-10-29T20:08:20.985Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/0xxx/CVE-2025-0694.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-0694","state":"PUBLISHED","datePublished":"2025-03-18T11:04:06.167Z","dateUpdated":"2025-03-18T13:09:54.473Z","assignerShortName":"CERTVDE","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateReserved":"2025-01-24T08:27:09.159Z"},"containers":{"cna":{"title":"CODESYS Control V3 removable media path traversal","descriptions":[{"lang":"en","value":"Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access."}],"affected":[{"vendor":"CODESYS","product":"CODESYS Control for BeagleBone SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for emPC-A/iMX6 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for IOT2000 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux ARM SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC100 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC200 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PLCnext SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Raspberry Pi SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for WAGO Touch Panels 600 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (for Beckhoff CX) SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"3.5.21.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (SL)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"3.5.21.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control Win (SL)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"3.5.21.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Runtime Toolkit","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"3.5.21.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Virtual Control SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.16.0.0","versionType":"semver"}]}],"references":[{"url":"https://cert.vde.com/en/advisories/VDE-2025-015"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"PHYSICAL","availabilityImpact":"HIGH","baseScore":6.6,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-22","description":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"CERTVDE","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateUpdated":"2025-03-18T11:04:06.167Z"},"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"D. Blagojevic, S.Dietz and T. Weber from CyberDanube"}],"source":{"advisory":"VDE-2025-015","defect":["CERT@VDE#641743"],"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-03-18T13:09:24.499918Z","id":"CVE-2025-0694","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-03-18T13:09:54.473Z"}}]}}}