{"id":"CVE-2025-0665","state":"PUBLISHED","title":"eventfd double close","description":"libcurl would wrongly close the same eventfd file descriptor twice when taking\ndown a connection channel after having completed a threaded name resolve.","publishedAt":"2025-02-05T09:16:49.038Z","updatedAt":"2026-10-15T01:01:54.492Z","severity":{"score":7,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H","source":"CISA-ADP"},"assigner":"curl","products":["curl curl"],"affected":[{"vendor":"curl","product":"curl","defaultStatus":"unaffected","versions":[{"version":"8.11.1","status":"affected","lessThanOrEqual":"8.11.1","versionType":"semver"}]}],"references":["https://curl.se/docs/CVE-2025-0665.json","https://curl.se/docs/CVE-2025-0665.html","https://hackerone.com/reports/2954286","http://www.openwall.com/lists/oss-security/2025/02/05/2","http://www.openwall.com/lists/oss-security/2025/02/05/5","https://security.netapp.com/advisory/ntap-20250306-0007/","https://cert-portal.siemens.com/productcert/html/ssa-398330.html","https://cert-portal.siemens.com/productcert/html/ssa-089022.html"],"weaknesses":[],"ingestedAt":"2026-10-29T20:08:20.985Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/0xxx/CVE-2025-0665.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-0665","state":"PUBLISHED","datePublished":"2025-02-05T09:16:49.038Z","dateUpdated":"2026-10-15T01:01:54.492Z","assignerShortName":"curl","assignerOrgId":"2499f714-1537-4658-8207-48ae4bb9eae9","dateReserved":"2025-01-23T08:40:34.867Z"},"containers":{"cna":{"title":"eventfd double close","descriptions":[{"lang":"en","value":"libcurl would wrongly close the same eventfd file descriptor twice when taking\ndown a connection channel after having completed a threaded name resolve."}],"affected":[{"vendor":"curl","product":"curl","defaultStatus":"unaffected","versions":[{"version":"8.11.1","status":"affected","lessThanOrEqual":"8.11.1","versionType":"semver"}]}],"references":[{"url":"https://curl.se/docs/CVE-2025-0665.json","name":"json"},{"url":"https://curl.se/docs/CVE-2025-0665.html","name":"www"},{"url":"https://hackerone.com/reports/2954286","name":"issue"}],"problemTypes":[{"descriptions":[{"lang":"en","description":"CWE-1341 Multiple Releases of Same Resource or Handle"}]}],"providerMetadata":{"shortName":"curl","orgId":"2499f714-1537-4658-8207-48ae4bb9eae9","dateUpdated":"2025-02-05T09:16:49.038Z"},"credits":[{"lang":"en","value":"Christian Heusel","type":"finder"},{"lang":"en","value":"Andy Pan","type":"remediation developer"}]},"adp":[{"title":"CVE Program Container","references":[{"url":"http://www.openwall.com/lists/oss-security/2025/02/05/2"},{"url":"http://www.openwall.com/lists/oss-security/2025/02/05/5"},{"url":"https://security.netapp.com/advisory/ntap-20250306-0007/"}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2025-03-07T00:10:49.291Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":7,"attackVector":"NETWORK","baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H","integrityImpact":"LOW","userInteraction":"NONE","attackComplexity":"HIGH","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"LOW"}},{"other":{"type":"ssvc","content":{"timestamp":"2026-03-17T17:42:03.317434Z","id":"CVE-2025-0665","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-03-17T17:42:06.679Z"}},{"affected":[{"vendor":"Siemens","product":"RUGGEDCOM RST2428P","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XCH328","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XCM324","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XCM328","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XCM332","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRH334 (24 V DC, 8xFO, CC)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 12xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 8xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 12xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 8xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (2x230 V AC, 12xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (2x230 V AC, 8xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"V3.1.0","status":"affected","lessThan":"V3.1.5","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"V3.1.0","status":"affected","lessThan":"V3.1.5","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"V3.1.0","status":"affected","lessThan":"V3.1.5","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"V3.1.0","status":"affected","lessThan":"V3.1.5","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"V3.1.0","status":"affected","lessThan":"V3.1.5","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-398330.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-089022.html"}],"providerMetadata":{"shortName":"siemens-SADP","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","dateUpdated":"2026-10-15T01:01:54.492Z"},"x_adpType":"supplier"}]}}}