{"id":"CVE-2025-0327","state":"PUBLISHED","title":"CWE-269: Improper Privilege Management vulnerability exists for two services (of which one managing audit","description":"CWE-269: Improper Privilege Management vulnerability exists for two services (of which one managing audit\ntrail data and the other acting as server managing client request) that could cause a loss of Confidentiality,\nIntegrity and Availability of engineering workstation when an attacker with standard privilege modifies the\nexecutable path of the windows services. To be exploited, services need to be restarted.","publishedAt":"2025-02-13T06:20:26.852Z","updatedAt":"2025-02-13T14:56:12.017Z","severity":{"score":8.5,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"schneider"},"assigner":"schneider","products":["Schneider Electric EcoStruxure Process Expert","Schneider Electric EcoStruxure Process Expert for AVEVA System Platform"],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure Process Expert","defaultStatus":"unaffected","versions":[{"version":"Versions 2020R2","status":"affected"},{"version":"Versions  2021 & 2023 (prior to v4.8.0.5715)","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure Process Expert for AVEVA System Platform","defaultStatus":"unaffected","versions":[{"version":"Versions 2020R2","status":"affected"},{"version":"Versions  2021 & 2023","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-042-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-042-03.pdf"],"weaknesses":["CWE-269"],"ingestedAt":"2026-10-29T20:08:20.985Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/0xxx/CVE-2025-0327.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-0327","state":"PUBLISHED","datePublished":"2025-02-13T06:20:26.852Z","dateUpdated":"2025-02-13T14:56:12.017Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2025-01-08T13:34:15.419Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"CWE-269: Improper Privilege Management vulnerability exists for two services (of which one managing audit\ntrail data and the other acting as server managing client request) that could cause a loss of Confidentiality,\nIntegrity and Availability of engineering workstation when an attacker with standard privilege modifies the\nexecutable path of the windows services. To be exploited, services need to be restarted."}],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure Process Expert","defaultStatus":"unaffected","versions":[{"version":"Versions 2020R2","status":"affected"},{"version":"Versions  2021 & 2023 (prior to v4.8.0.5715)","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure Process Expert for AVEVA System Platform","defaultStatus":"unaffected","versions":[{"version":"Versions 2020R2","status":"affected"},{"version":"Versions  2021 & 2023","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-042-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-042-03.pdf"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.5,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-269","description":"CWE-269 Improper Privilege Management","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2025-02-13T06:20:26.852Z"},"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-13T14:55:58.362547Z","id":"CVE-2025-0327","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-02-13T14:56:12.017Z"}}]}}}