{"id":"CVE-2024-7986","state":"PUBLISHED","title":"Rockwell Automation ThinManager® ThinServer™ Information Disclosure","description":"A vulnerability exists in the Rockwell Automation ThinManager® ThinServer that allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer™ service to read arbitrary files by creating a junction that points to the target directory.","publishedAt":"2024-08-23T11:51:55.080Z","updatedAt":"2024-08-28T16:21:02.832Z","severity":{"score":6.8,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","source":"Rockwell"},"assigner":"Rockwell","products":["Rockwell Automation ThinManager® ThinServer™"],"affected":[{"vendor":"Rockwell Automation","product":"ThinManager® ThinServer™","defaultStatus":"unaffected","versions":[{"version":"11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1","status":"affected"}]}],"references":["https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html"],"weaknesses":["CWE-732"],"ingestedAt":"2026-10-29T20:08:20.985Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/7xxx/CVE-2024-7986.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-7986","state":"PUBLISHED","datePublished":"2024-08-23T11:51:55.080Z","dateUpdated":"2024-08-28T16:21:02.832Z","assignerShortName":"Rockwell","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","dateReserved":"2024-08-19T20:06:24.873Z"},"containers":{"cna":{"title":"Rockwell Automation ThinManager® ThinServer™ Information Disclosure","descriptions":[{"lang":"en","value":"A vulnerability exists in the Rockwell Automation ThinManager® ThinServer that allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer™ service to read arbitrary files by creating a junction that points to the target directory."}],"affected":[{"vendor":"Rockwell Automation","product":"ThinManager® ThinServer™","defaultStatus":"unaffected","versions":[{"version":"11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1","status":"affected"}]}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":6.8,"baseSeverity":"MEDIUM","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-732","description":"CWE-732 Incorrect Permission Assignment for Critical Resource","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Rockwell","orgId":"b73dd486-f505-4403-b634-40b078b177f0","dateUpdated":"2024-08-23T11:51:55.080Z"},"datePublic":"2024-08-22T13:00:00.000Z","impacts":[{"capecId":"CAPEC-576","descriptions":[{"lang":"en","value":"CAPEC-576 Group Permission Footprinting"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<table><tbody><tr><td><p>Affected Product</p></td><td><p>First Known in software version</p></td><td><p>Corrected in software version</p></td></tr><tr><td><p>ThinManager® ThinServer™</p></td><td><p>11.1.0-11.1.7<br>11.2.0-11.2.8<br>12.0.0-12.0.6<br>12.1.0-12.1.7<br>13.0.0-13.0.4<br>13.1.0-13.1.2<br>13.2.0-13.2.1</p></td><td><p>11.1.8</p><p>11.2.9</p><p>12.0.7</p><p>12.1.8</p><p>13.0.5</p><p>13.1.3</p><p>13.2.2</p></td></tr></tbody></table><br><p><b>Mitigations and Workarounds</b></p><p>Customers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.</p><p>· &nbsp; &nbsp; &nbsp; <a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">Security Best Practices</a></p>"}],"value":"Affected Product\n\nFirst Known in software version\n\nCorrected in software version\n\nThinManager® ThinServer™\n\n11.1.0-11.1.7\n11.2.0-11.2.8\n12.0.0-12.0.6\n12.1.0-12.1.7\n13.0.0-13.0.4\n13.1.0-13.1.2\n13.2.0-13.2.1\n\n11.1.8\n\n11.2.9\n\n12.0.7\n\n12.1.8\n\n13.0.5\n\n13.1.3\n\n13.2.2\n\n\nMitigations and Workarounds\n\nCustomers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.\n\n·        Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"}],"source":{"advisory":"SD1692","discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-28T16:20:54.169556Z","id":"CVE-2024-7986","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-08-28T16:21:02.832Z"}}]}}}