{"id":"CVE-2024-7513","state":"PUBLISHED","title":"Rockwell Automation FactoryTalk® View Site Edition Code Execution Vulnerability via File Permissions","description":"CVE-2024-7513 IMPACT\n\nA code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions.","publishedAt":"2024-08-14T19:48:46.656Z","updatedAt":"2025-08-15T13:03:12.526Z","severity":{"score":8.5,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"Rockwell"},"assigner":"Rockwell","products":["Rockwell Automation FactoryTalk View Site Edition"],"affected":[{"vendor":"Rockwell Automation","product":"FactoryTalk View Site Edition","defaultStatus":"unaffected","versions":[{"version":"13.0","status":"affected"}]}],"references":["https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201688.html"],"weaknesses":["CWE-732"],"ingestedAt":"2026-10-29T20:08:20.985Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/7xxx/CVE-2024-7513.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-7513","state":"PUBLISHED","datePublished":"2024-08-14T19:48:46.656Z","dateUpdated":"2025-08-15T13:03:12.526Z","assignerShortName":"Rockwell","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","dateReserved":"2024-08-05T20:18:13.759Z"},"containers":{"cna":{"title":"Rockwell Automation FactoryTalk® View Site Edition Code Execution Vulnerability via File Permissions","descriptions":[{"lang":"en","value":"CVE-2024-7513 IMPACT\n\nA code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions."}],"affected":[{"vendor":"Rockwell Automation","product":"FactoryTalk View Site Edition","defaultStatus":"unaffected","versions":[{"version":"13.0","status":"affected"}]}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201688.html"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.5,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-732","description":"CWE-732 Incorrect Permission Assignment for Critical Resource","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Rockwell","orgId":"b73dd486-f505-4403-b634-40b078b177f0","dateUpdated":"2025-08-15T13:03:12.526Z"},"datePublic":"2024-08-13T13:00:00.000Z","impacts":[{"capecId":"CAPEC-576","descriptions":[{"lang":"en","value":"CAPEC-576 Group Permission Footprinting"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Upgrade to v15.0"}],"value":"Upgrade to v15.0"}],"source":{"discovery":"INTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Customers using the affected software are encouraged to apply security best practices, if possible.</p><ul><li><p>Remove “Everyone” user group from read and write privileges by changing the FactoryTalk® View SE project folder permissions using the help guide. Detailed instructions are below. </p></li></ul><ul><li><p>Open FactoryTalk® View Studio -&gt; Help -&gt; FactoryTalk® View SE Help. I<span style=\"background-color: var(--wht);\">n the file -&gt; Security -&gt; “HMI projects folder”</span></p></li></ul>\n\n<br>"}],"value":"Customers using the affected software are encouraged to apply security best practices, if possible.\n\n  *  Remove “Everyone” user group from read and write privileges by changing the FactoryTalk® View SE project folder permissions using the help guide. Detailed instructions are below. \n\n\n\n\n  *  Open FactoryTalk® View Studio -> Help -> FactoryTalk® View SE Help. In the file -> Security -> “HMI projects folder”"}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"rockwellautomation","product":"factorytalk_view","defaultStatus":"unaffected","versions":[{"version":"13.0","status":"affected"}],"cpes":["cpe:2.3:a:rockwellautomation:factorytalk_view:13.0:*:*:*:se:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-14T20:09:08.721442Z","id":"CVE-2024-7513","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-08-14T20:16:25.948Z"}}]}}}