{"id":"CVE-2024-6528","state":"PUBLISHED","title":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site","description":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site\nScripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting\ncondition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a\npage containing the injected payload.","publishedAt":"2024-07-11T09:03:27.074Z","updatedAt":"2024-08-01T21:41:03.525Z","severity":{"score":5.4,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","source":"schneider"},"assigner":"schneider","products":["Schneider Electric Modicon Controllers M241 / M251","Schneider Electric Modicon Controllers M258 / LMC058","Schneider Electric Modicon Controllers M262"],"affected":[{"vendor":"Schneider Electric","product":"Modicon Controllers M241 / M251","defaultStatus":"unaffected","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"Modicon Controllers M258 / LMC058","defaultStatus":"unaffected","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"Modicon Controllers M262","defaultStatus":"unaffected","versions":[{"version":"All Versions","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-04.pdf"],"weaknesses":["CWE-79"],"ingestedAt":"2026-10-29T20:08:12.933Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/6xxx/CVE-2024-6528.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-6528","state":"PUBLISHED","datePublished":"2024-07-11T09:03:27.074Z","dateUpdated":"2024-08-01T21:41:03.525Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2024-07-05T09:35:52.875Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site\nScripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting\ncondition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a\npage containing the injected payload."}],"affected":[{"vendor":"Schneider Electric","product":"Modicon Controllers M241 / M251","defaultStatus":"unaffected","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"Modicon Controllers M258 / LMC058","defaultStatus":"unaffected","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"Modicon Controllers M262","defaultStatus":"unaffected","versions":[{"version":"All Versions","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-04.pdf"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.4,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2024-07-11T09:03:27.074Z"},"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-29T20:04:30.600996Z","id":"CVE-2024-6528","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-07-29T20:04:38.247Z"}},{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-04.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T21:41:03.525Z"}}]}}}