{"id":"CVE-2024-54005","state":"PUBLISHED","title":"A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10","description":"A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by injecting malicious data into the communication channel between the two systems.","publishedAt":"2024-12-10T13:54:15.994Z","updatedAt":"2024-12-10T17:17:46.788Z","severity":{"score":5.9,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens COMOS V10.3","Siemens COMOS V10.4.0","Siemens COMOS V10.4.1","Siemens COMOS V10.4.2","Siemens COMOS V10.4.3","Siemens COMOS V10.4.4","Siemens COMOS V10.4.4.1"],"affected":[{"vendor":"Siemens","product":"COMOS V10.3","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.3.3.5.8","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.0","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.2","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.3","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.4.3.0.47","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.4.4.2","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.4.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.4.4.1.21","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-701627.html"],"weaknesses":["CWE-611"],"ingestedAt":"2026-10-29T20:08:04.920Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/54xxx/CVE-2024-54005.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-54005","state":"PUBLISHED","datePublished":"2024-12-10T13:54:15.994Z","dateUpdated":"2024-12-10T17:17:46.788Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-11-26T16:33:29.218Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by injecting malicious data into the communication channel between the two systems."}],"affected":[{"vendor":"Siemens","product":"COMOS V10.3","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.3.3.5.8","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.0","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.2","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.3","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.4.3.0.47","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.4.4.2","versionType":"custom"}]},{"vendor":"Siemens","product":"COMOS V10.4.4.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.4.4.1.21","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-701627.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":5.1,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","baseScore":5.9,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-611","lang":"en","description":"CWE-611: Improper Restriction of XML External Entity Reference","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-12-10T13:54:15.994Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-12-10T15:16:40.996944Z","id":"CVE-2024-54005","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-12-10T17:17:46.788Z"}}]}}}