{"id":"CVE-2024-52334","state":"PUBLISHED","title":"A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF07). The affected application does not encrypt the passwords properly.\r","description":"A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF07). The affected application does not encrypt the passwords properly.\r\nThis could allow an attacker to recover the original passwords and might gain unauthorized access.","publishedAt":"2026-02-10T09:58:33.733Z","updatedAt":"2026-02-10T19:52:41.934Z","severity":{"score":6.3,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens syngo.plaza VB30E"],"affected":[{"vendor":"Siemens","product":"syngo.plaza VB30E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"VB30E_HF07","versionType":"custom"}]}],"references":["https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-016040"],"weaknesses":["CWE-261"],"ingestedAt":"2026-10-29T20:08:04.920Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/52xxx/CVE-2024-52334.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2024-52334","state":"PUBLISHED","datePublished":"2026-02-10T09:58:33.733Z","dateUpdated":"2026-02-10T19:52:41.934Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-11-08T12:49:09.651Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF07). The affected application does not encrypt the passwords properly.\r\nThis could allow an attacker to recover the original passwords and might gain unauthorized access."}],"affected":[{"vendor":"Siemens","product":"syngo.plaza VB30E","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"VB30E_HF07","versionType":"custom"}]}],"references":[{"url":"https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-016040"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":5.3,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","baseScore":6.3,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-261","lang":"en","description":"CWE-261: Weak Encoding for Password","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2026-02-10T09:58:33.733Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-02-10T19:52:26.366140Z","id":"CVE-2024-52334","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-02-10T19:52:41.934Z"}}]}}}