{"id":"CVE-2024-47553","state":"PUBLISHED","title":"A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate user input to the ```ssmctl-client``` com","description":"A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate user input to the ```ssmctl-client``` command.\r\nThis could allow an authenticated, lowly privileged remote attacker to execute arbitrary code with root privileges on the underlying OS.","publishedAt":"2024-10-08T08:40:50.371Z","updatedAt":"2026-03-10T16:07:39.223Z","severity":{"score":9.4,"label":"Critical","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","source":"siemens"},"assigner":"siemens","products":["Siemens SINEC Security Monitor"],"affected":[{"vendor":"Siemens","product":"SINEC Security Monitor","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.9.0","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-430425.html"],"weaknesses":["CWE-88"],"ingestedAt":"2026-10-29T20:07:56.516Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/47xxx/CVE-2024-47553.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2024-47553","state":"PUBLISHED","datePublished":"2024-10-08T08:40:50.371Z","dateUpdated":"2026-03-10T16:07:39.223Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-09-26T13:01:20.792Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate user input to the ```ssmctl-client``` command.\r\nThis could allow an authenticated, lowly privileged remote attacker to execute arbitrary code with root privileges on the underlying OS."}],"affected":[{"vendor":"Siemens","product":"SINEC Security Monitor","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.9.0","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-430425.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":9.9,"baseSeverity":"CRITICAL"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","baseScore":9.4,"baseSeverity":"CRITICAL"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-88","lang":"en","description":"CWE-88: Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2026-03-10T16:07:39.223Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"sinec_security_monitor","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"4.9.0","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:sinec_security_monitor:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-08T16:37:05.261541Z","id":"CVE-2024-47553","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-10-08T16:37:31.430Z"}}]}}}