{"id":"CVE-2024-4639","state":"PUBLISHED","title":"OnCell G3470A-LTE Series: Authenticated Command Injection via webDelIPSec","description":"OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.","publishedAt":"2024-06-25T09:15:03.229Z","updatedAt":"2024-08-01T20:47:41.194Z","severity":{"score":7.1,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N","source":"Moxa"},"assigner":"Moxa","products":["Moxa OnCell G3150A-LTE Series"],"affected":[{"vendor":"Moxa","product":"OnCell G3150A-LTE Series","defaultStatus":"unaffected","versions":[{"version":"1.0","status":"affected","lessThanOrEqual":"1.7.7","versionType":"custom"}]}],"references":["https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"],"weaknesses":["CWE-77"],"ingestedAt":"2026-10-29T20:07:56.516Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/4xxx/CVE-2024-4639.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-4639","state":"PUBLISHED","datePublished":"2024-06-25T09:15:03.229Z","dateUpdated":"2024-08-01T20:47:41.194Z","assignerShortName":"Moxa","assignerOrgId":"2e0a0ee2-d866-482a-9f5e-ac03d156dbaa","dateReserved":"2024-05-08T00:44:42.405Z"},"containers":{"cna":{"title":"OnCell G3470A-LTE Series: Authenticated Command Injection via webDelIPSec","descriptions":[{"lang":"en","value":"OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."}],"affected":[{"vendor":"Moxa","product":"OnCell G3150A-LTE Series","defaultStatus":"unaffected","versions":[{"version":"1.0","status":"affected","lessThanOrEqual":"1.7.7","versionType":"custom"}]}],"references":[{"url":"https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-77","description":"CWE-77: Improper Neutralization of Special Elements used in a Command","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Moxa","orgId":"2e0a0ee2-d866-482a-9f5e-ac03d156dbaa","dateUpdated":"2024-06-25T09:15:03.229Z"},"credits":[{"lang":"en","type":"finder","value":"Nikita Abramov from Positive Technologies"}],"impacts":[{"capecId":"CAPEC-248","descriptions":[{"lang":"en","value":"CAPEC-248: Command Injection"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.<br><ul><li>OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\">security patch (v1.7.8).</a></li></ul>"}],"value":"Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"}],"source":{"discovery":"EXTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Moxa recommends users to implement the following mitigations if necessary: </p><ul><li>Minimize network exposure to ensure the device is not accessible from the Internet. </li><li>When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). </li><li>The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware. </li></ul>"}],"value":"Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-06-25T13:34:53.804173Z","id":"CVE-2024-4639","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-06-25T13:35:01.665Z"}},{"title":"CVE Program Container","references":[{"url":"https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities","tags":["vendor-advisory","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T20:47:41.194Z"}}]}}}