{"id":"CVE-2024-45826","state":"PUBLISHED","title":"ThinManager® Code Execution Vulnerability","description":"CVE-2024-45826 IMPACT\nDue to improper input validation, a path traversal and remote code execution vulnerability exists when the ThinManager® processes a crafted POST request. If exploited, a user can install an executable file.","publishedAt":"2024-09-12T14:33:44.373Z","updatedAt":"2024-09-12T14:58:34.096Z","severity":{"score":8.5,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"Rockwell"},"assigner":"Rockwell","products":["Rockwell Automation ThinManager"],"affected":[{"vendor":"Rockwell Automation","product":"ThinManager","defaultStatus":"unaffected","versions":[{"version":"13.1.0-13.1.2","status":"affected"}]},{"vendor":"Rockwell Automation","product":"ThinManager","defaultStatus":"unaffected","versions":[{"version":"13.2.0-13.2.1","status":"affected"}]}],"references":["https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1700.html"],"weaknesses":["CWE-610"],"ingestedAt":"2026-10-29T20:07:47.831Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/45xxx/CVE-2024-45826.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-45826","state":"PUBLISHED","datePublished":"2024-09-12T14:33:44.373Z","dateUpdated":"2024-09-12T14:58:34.096Z","assignerShortName":"Rockwell","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","dateReserved":"2024-09-09T19:33:02.444Z"},"containers":{"cna":{"title":"ThinManager® Code Execution Vulnerability","descriptions":[{"lang":"en","value":"CVE-2024-45826 IMPACT\nDue to improper input validation, a path traversal and remote code execution vulnerability exists when the ThinManager® processes a crafted POST request. If exploited, a user can install an executable file."}],"affected":[{"vendor":"Rockwell Automation","product":"ThinManager","defaultStatus":"unaffected","versions":[{"version":"13.1.0-13.1.2","status":"affected"}]},{"vendor":"Rockwell Automation","product":"ThinManager","defaultStatus":"unaffected","versions":[{"version":"13.2.0-13.2.1","status":"affected"}]}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1700.html"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.5,"baseSeverity":"HIGH","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.8,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-610","description":"CWE-610 Externally Controlled Reference to a Resource in Another Sphere","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Rockwell","orgId":"b73dd486-f505-4403-b634-40b078b177f0","dateUpdated":"2024-09-12T14:33:44.373Z"},"datePublic":"2024-09-12T13:00:00.000Z","impacts":[{"capecId":"CAPEC-549","descriptions":[{"lang":"en","value":"CAPEC-549 Local Execution of Code"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Upgrade to V13.1.3 or V13.2.2"}],"value":"Upgrade to V13.1.3 or V13.2.2"}],"source":{"discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"rockwellautomation","product":"thinmanager","defaultStatus":"unaffected","versions":[{"version":"13.1.0","status":"affected","lessThan":"13.1.3","versionType":"custom"},{"version":"13.2.0","status":"affected","lessThan":"13.2.2","versionType":"custom"}],"cpes":["cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-09-12T14:57:00.839917Z","id":"CVE-2024-45826","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-09-12T14:58:34.096Z"}}]}}}