{"id":"CVE-2024-45476","state":"PUBLISHED","title":"A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualizat","description":"A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted WRL files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.","publishedAt":"2024-10-08T08:40:38.819Z","updatedAt":"2024-12-10T13:53:49.212Z","severity":{"score":4.8,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens Teamcenter Visualization V14.2","Siemens Teamcenter Visualization V14.3","Siemens Teamcenter Visualization V2312","Siemens Tecnomatix Plant Simulation V2302","Siemens Tecnomatix Plant Simulation V2404"],"affected":[{"vendor":"Siemens","product":"Teamcenter Visualization V14.2","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V14.2.0.14","versionType":"custom"}]},{"vendor":"Siemens","product":"Teamcenter Visualization V14.3","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V14.3.0.12","versionType":"custom"}]},{"vendor":"Siemens","product":"Teamcenter Visualization V2312","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2312.0008","versionType":"custom"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2302.0016","versionType":"custom"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2404","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2404.0005","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-583523.html","https://cert-portal.siemens.com/productcert/html/ssa-645131.html"],"weaknesses":["CWE-476"],"ingestedAt":"2026-10-29T20:07:47.831Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/45xxx/CVE-2024-45476.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-45476","state":"PUBLISHED","datePublished":"2024-10-08T08:40:38.819Z","dateUpdated":"2024-12-10T13:53:49.212Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-08-29T11:28:48.106Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted WRL files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."}],"affected":[{"vendor":"Siemens","product":"Teamcenter Visualization V14.2","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V14.2.0.14","versionType":"custom"}]},{"vendor":"Siemens","product":"Teamcenter Visualization V14.3","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V14.3.0.12","versionType":"custom"}]},{"vendor":"Siemens","product":"Teamcenter Visualization V2312","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2312.0008","versionType":"custom"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2302.0016","versionType":"custom"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2404","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2404.0005","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-583523.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-645131.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L","baseScore":3.3,"baseSeverity":"LOW"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N","baseScore":4.8,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-476","lang":"en","description":"CWE-476: NULL Pointer Dereference","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-12-10T13:53:49.212Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-08T17:23:31.015742Z","id":"CVE-2024-45476","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-10-08T17:23:40.620Z"}}]}}}