{"id":"CVE-2024-4252","state":"PUBLISHED","title":"Tenda i22 formSetUrlFilterRule stack-based overflow","description":"A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","publishedAt":"2024-04-27T13:31:04.906Z","updatedAt":"2024-08-01T20:33:53.167Z","severity":{"score":8.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"VulDB"},"assigner":"VulDB","products":["Tenda i22"],"affected":[{"vendor":"Tenda","product":"i22","versions":[{"version":"1.0.0.3(4687)","status":"affected"}]}],"references":["https://vuldb.com/?id.262143","https://vuldb.com/?ctiid.262143","https://vuldb.com/?submit.319840","https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md"],"weaknesses":["CWE-121"],"ingestedAt":"2026-10-29T20:07:56.516Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/4xxx/CVE-2024-4252.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-4252","state":"PUBLISHED","datePublished":"2024-04-27T13:31:04.906Z","dateUpdated":"2024-08-01T20:33:53.167Z","assignerShortName":"VulDB","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateReserved":"2024-04-26T12:40:45.945Z"},"containers":{"cna":{"title":"Tenda i22 formSetUrlFilterRule stack-based overflow","descriptions":[{"lang":"en","value":"A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"Es wurde eine Schwachstelle in Tenda i22 1.0.0.3(4687) entdeckt. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formSetUrlFilterRule. Mit der Manipulation des Arguments groupIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen."}],"affected":[{"vendor":"Tenda","product":"i22","versions":[{"version":"1.0.0.3(4687)","status":"affected"}]}],"references":[{"url":"https://vuldb.com/?id.262143","name":"VDB-262143 | Tenda i22 formSetUrlFilterRule stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.262143","name":"VDB-262143 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.319840","name":"Submit #319840 | Tenda i22 V1.0.0.3(4687) Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md","tags":["related"]}],"metrics":[{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","type":"CWE","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"providerMetadata":{"shortName":"VulDB","orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateUpdated":"2024-04-27T13:31:04.906Z"},"timeline":[{"time":"2024-04-26T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-04-26T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-04-26T14:46:27.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_tu (VulDB User)","type":"reporter"}]},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"tenda","product":"i22_firmware","defaultStatus":"unknown","versions":[{"version":"1.0.0.3\\(4687\\)","status":"affected"}],"cpes":["cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-04-30T19:51:45.729808Z","id":"CVE-2024-4252","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-07-23T17:43:07.157Z"}},{"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.262143","name":"VDB-262143 | Tenda i22 formSetUrlFilterRule stack-based overflow","tags":["vdb-entry","technical-description","x_transferred"]},{"url":"https://vuldb.com/?ctiid.262143","name":"VDB-262143 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://vuldb.com/?submit.319840","name":"Submit #319840 | Tenda i22 V1.0.0.3(4687) Buffer Overflow","tags":["third-party-advisory","x_transferred"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md","tags":["related","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T20:33:53.167Z"}}]}}}