{"id":"CVE-2024-41967","state":"PUBLISHED","title":"WAGO: Boot Mode Manipulation in Multiple Devices","description":"A low privileged remote attacker may modify the boot mode configuration setup of the device, leading to modification of the firmware upgrade process or a denial-of-service attack.","publishedAt":"2024-11-18T09:03:57.513Z","updatedAt":"2025-08-27T21:33:03.997Z","severity":{"score":8.1,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","source":"CERTVDE"},"assigner":"CERTVDE","products":["WAGO CC100 0751-9x01","WAGO PFC100 G2 0750-811x-xxxx-xxxx","WAGO PFC200 G2 750-821x-xxx-xxx","WAGO TP600 0762-420x/8000-000x","WAGO TP600 0762-430x/8000-000x","WAGO TP600 0762-520x/8000-000x","WAGO TP600 0762-530x/8000-000x","WAGO TP600 0762-620x/8000-000x","WAGO TP600 0762-630x/8000-000x","WAGO Edge Controller 0752-8303/8000-0002","WAGO PFC100 G1 0750-810x/xxxx-xxxx","WAGO PFC200 G1 750-820x-xxx-xxx","WAGO PFC200 G1 0750-820x/xxx-xxx","WAGO PFC200 G2 0750-821x/xxx-xxx","WAGO CC100 0751/9x01"],"affected":[{"vendor":"WAGO","product":"CC100 0751-9x01","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC100 G2 0750-811x-xxxx-xxxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC200 G2 750-821x-xxx-xxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-420x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-430x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-520x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-530x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-620x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-630x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"Edge Controller 0752-8303/8000-0002","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC100 G1 0750-810x/xxxx-xxxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"3.10.10 (FW22 Patch 1)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC200 G1 750-820x-xxx-xxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"3.10.10 (FW22 Patch 1)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC200 G1 0750-820x/xxx-xxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"03.03.08 (80)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC200 G2 0750-821x/xxx-xxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"04.04.03 (70)","versionType":"semver"}]},{"vendor":"WAGO","product":"CC100 0751/9x01","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"04.03.03 (72)","versionType":"semver"}]},{"vendor":"WAGO","product":"CC100 0751/9x01","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"04.04.03 (70)","versionType":"semver"}]}],"references":["https://cert.vde.com/en/advisories/VDE-2024-047"],"weaknesses":["CWE-306"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/41xxx/CVE-2024-41967.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-41967","state":"PUBLISHED","datePublished":"2024-11-18T09:03:57.513Z","dateUpdated":"2025-08-27T21:33:03.997Z","assignerShortName":"CERTVDE","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateReserved":"2024-07-25T09:07:31.463Z"},"containers":{"cna":{"title":"WAGO: Boot Mode Manipulation in Multiple Devices","descriptions":[{"lang":"en","value":"A low privileged remote attacker may modify the boot mode configuration setup of the device, leading to modification of the firmware upgrade process or a denial-of-service attack."}],"affected":[{"vendor":"WAGO","product":"CC100 0751-9x01","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC100 G2 0750-811x-xxxx-xxxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC200 G2 750-821x-xxx-xxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-420x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-430x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-520x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-530x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-620x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"TP600 0762-630x/8000-000x","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"Edge Controller 0752-8303/8000-0002","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"4.5.10 (FW27)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC100 G1 0750-810x/xxxx-xxxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"3.10.10 (FW22 Patch 1)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC200 G1 750-820x-xxx-xxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"3.10.10 (FW22 Patch 1)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC200 G1 0750-820x/xxx-xxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"03.03.08 (80)","versionType":"semver"}]},{"vendor":"WAGO","product":"PFC200 G2 0750-821x/xxx-xxx","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"04.04.03 (70)","versionType":"semver"}]},{"vendor":"WAGO","product":"CC100 0751/9x01","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"04.03.03 (72)","versionType":"semver"}]},{"vendor":"WAGO","product":"CC100 0751/9x01","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThanOrEqual":"04.04.03 (70)","versionType":"semver"}]}],"references":[{"url":"https://cert.vde.com/en/advisories/VDE-2024-047"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306 Missing Authentication for Critical Function","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"CERTVDE","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateUpdated":"2025-01-30T09:19:19.853Z"},"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Diego Giubertoni"},{"lang":"en","type":"reporter","user":"00000000-0000-4000-9000-000000000000","value":"Nozomi Networks"}],"source":{"advisory":"VDE-2024-047","defect":["CERT@VDE#641658"],"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":8.1,"attackVector":"NETWORK","baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"LOW","confidentialityImpact":"NONE"}},{"other":{"type":"ssvc","content":{"id":"CVE-2024-41967","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-11-18T15:22:03.669949Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-08-27T21:33:03.997Z"}}]}}}