{"id":"CVE-2024-41939","state":"PUBLISHED","title":"A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated a","description":"A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and elevate their privileges on the application.","publishedAt":"2024-08-13T07:54:31.595Z","updatedAt":"2024-08-13T14:21:41.360Z","severity":{"score":8.7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens SINEC NMS"],"affected":[{"vendor":"Siemens","product":"SINEC NMS","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-784301.html"],"weaknesses":["CWE-863"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/41xxx/CVE-2024-41939.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-41939","state":"PUBLISHED","datePublished":"2024-08-13T07:54:31.595Z","dateUpdated":"2024-08-13T14:21:41.360Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-07-24T14:47:36.388Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and elevate their privileges on the application."}],"affected":[{"vendor":"Siemens","product":"SINEC NMS","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-784301.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":8.8,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":8.7,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-863","lang":"en","description":"CWE-863: Incorrect Authorization","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-08-13T07:54:31.595Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"sinec_nms","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"3.0","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-13T14:20:26.504156Z","id":"CVE-2024-41939","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-08-13T14:21:41.360Z"}}]}}}