{"id":"CVE-2024-41905","state":"PUBLISHED","title":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not have access control for accessing the file","description":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not have access control for accessing the files. This could allow an authenticated attacker with low privilege's to get access to sensitive information.","publishedAt":"2024-08-13T07:54:25.056Z","updatedAt":"2024-08-13T13:25:25.882Z","severity":{"score":7.6,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens SINEC Traffic Analyzer"],"affected":[{"vendor":"Siemens","product":"SINEC Traffic Analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.0","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-716317.html"],"weaknesses":["CWE-284"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/41xxx/CVE-2024-41905.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-41905","state":"PUBLISHED","datePublished":"2024-08-13T07:54:25.056Z","dateUpdated":"2024-08-13T13:25:25.882Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-07-23T10:56:51.268Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not have access control for accessing the files. This could allow an authenticated attacker with low privilege's to get access to sensitive information."}],"affected":[{"vendor":"Siemens","product":"SINEC Traffic Analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.0","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-716317.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N","baseScore":6.8,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N","baseScore":7.6,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-284","lang":"en","description":"CWE-284: Improper Access Control","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-08-13T07:54:25.056Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"sinec_traffic_analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"2.0","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-13T13:05:49.682793Z","id":"CVE-2024-41905","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-08-13T13:25:25.882Z"}}]}}}