{"id":"CVE-2024-41903","state":"PUBLISHED","title":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application mounts the container's root filesystem with read ","description":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application mounts the container's root filesystem with read and write privileges. This could allow an attacker to alter the container's filesystem leading to unauthorized modifications and data corruption.","publishedAt":"2024-08-13T07:54:22.465Z","updatedAt":"2024-08-13T14:22:58.678Z","severity":{"score":7.5,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens SINEC Traffic Analyzer"],"affected":[{"vendor":"Siemens","product":"SINEC Traffic Analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.0","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-716317.html"],"weaknesses":["CWE-269"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/41xxx/CVE-2024-41903.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-41903","state":"PUBLISHED","datePublished":"2024-08-13T07:54:22.465Z","dateUpdated":"2024-08-13T14:22:58.678Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-07-23T10:56:51.267Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application mounts the container's root filesystem with read and write privileges. This could allow an attacker to alter the container's filesystem leading to unauthorized modifications and data corruption."}],"affected":[{"vendor":"Siemens","product":"SINEC Traffic Analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.0","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-716317.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":6.6,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":7.5,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-269","lang":"en","description":"CWE-269: Improper Privilege Management","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-08-13T07:54:22.465Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"sinec_traffic_analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"2.0","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-13T14:22:03.946308Z","id":"CVE-2024-41903","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-08-13T14:22:58.678Z"}}]}}}