{"id":"CVE-2024-41902","state":"PUBLISHED","title":"A vulnerability has been identified in JT2Go (All versions < V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that could be triggered whil","description":"A vulnerability has been identified in JT2Go (All versions < V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.","publishedAt":"2024-10-08T08:40:18.170Z","updatedAt":"2024-10-08T18:03:27.584Z","severity":{"score":7.3,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens JT2Go"],"affected":[{"vendor":"Siemens","product":"JT2Go","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2406.0003","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-626178.html"],"weaknesses":["CWE-121"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/41xxx/CVE-2024-41902.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-41902","state":"PUBLISHED","datePublished":"2024-10-08T08:40:18.170Z","dateUpdated":"2024-10-08T18:03:27.584Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-07-23T10:56:51.267Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT2Go (All versions < V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process."}],"affected":[{"vendor":"Siemens","product":"JT2Go","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2406.0003","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-626178.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":7.3,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","lang":"en","description":"CWE-121: Stack-based Buffer Overflow","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-10-08T08:40:18.170Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"jt2go","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"2406.0003","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-08T18:02:30.732549Z","id":"CVE-2024-41902","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-10-08T18:03:27.584Z"}}]}}}