{"id":"CVE-2024-41788","state":"PUBLISHED","title":"A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the input parameters in specific GET","description":"A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the input parameters in specific GET requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.","publishedAt":"2025-04-08T08:22:00.872Z","updatedAt":"2025-04-08T13:24:24.996Z","severity":{"score":9.4,"label":"Critical","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","source":"siemens"},"assigner":"siemens","products":["Siemens SENTRON 7KT PAC1260 Data Manager"],"affected":[{"vendor":"Siemens","product":"SENTRON 7KT PAC1260 Data Manager","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-187636.html"],"weaknesses":["CWE-78"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/41xxx/CVE-2024-41788.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-41788","state":"PUBLISHED","datePublished":"2025-04-08T08:22:00.872Z","dateUpdated":"2025-04-08T13:24:24.996Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-07-22T13:19:53.375Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the input parameters in specific GET requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges."}],"affected":[{"vendor":"Siemens","product":"SENTRON 7KT PAC1260 Data Manager","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-187636.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":9.1,"baseSeverity":"CRITICAL"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","baseScore":9.4,"baseSeverity":"CRITICAL"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","lang":"en","description":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2025-04-08T08:22:00.872Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-08T13:24:09.499048Z","id":"CVE-2024-41788","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-08T13:24:24.996Z"}}]}}}