{"id":"CVE-2024-4169","state":"PUBLISHED","title":"Tenda 4G300 sub_4279CC stack-based overflow","description":"A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","publishedAt":"2024-04-25T12:31:04.756Z","updatedAt":"2024-08-01T20:33:52.514Z","severity":{"score":8.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"VulDB"},"assigner":"VulDB","products":["Tenda 4G300"],"affected":[{"vendor":"Tenda","product":"4G300","versions":[{"version":"1.01.42","status":"affected"}]}],"references":["https://vuldb.com/?id.261988","https://vuldb.com/?ctiid.261988","https://vuldb.com/?submit.318988","https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_42775C.md"],"weaknesses":["CWE-121"],"ingestedAt":"2026-10-29T20:07:56.516Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/4xxx/CVE-2024-4169.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-4169","state":"PUBLISHED","datePublished":"2024-04-25T12:31:04.756Z","dateUpdated":"2024-08-01T20:33:52.514Z","assignerShortName":"VulDB","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateReserved":"2024-04-25T04:41:33.737Z"},"containers":{"cna":{"title":"Tenda 4G300 sub_4279CC stack-based overflow","descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"In Tenda 4G300 1.01.42 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion sub_42775C/sub_4279CC. Dank Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen."}],"affected":[{"vendor":"Tenda","product":"4G300","versions":[{"version":"1.01.42","status":"affected"}]}],"references":[{"url":"https://vuldb.com/?id.261988","name":"VDB-261988 | Tenda 4G300 sub_4279CC stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.261988","name":"VDB-261988 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.318988","name":"Submit #318988 | Tenda 4G300 V1.01.42 Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_42775C.md","tags":["related"]}],"metrics":[{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","type":"CWE","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"providerMetadata":{"shortName":"VulDB","orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateUpdated":"2024-04-25T12:31:04.756Z"},"timeline":[{"time":"2024-04-25T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-04-25T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-04-25T06:46:40.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"wxhwxhwxh_tutu (VulDB User)","type":"reporter"}]},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"tenda","product":"4g300","defaultStatus":"unknown","versions":[{"version":"1.01.42","status":"affected"}],"cpes":["cpe:2.3:h:tenda:4g300:-:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-4169","role":"CISA Coordinator","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2024-04-25T16:16:36.621949Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-06-04T17:55:55.670Z"}},{"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.261988","name":"VDB-261988 | Tenda 4G300 sub_4279CC stack-based overflow","tags":["vdb-entry","technical-description","x_transferred"]},{"url":"https://vuldb.com/?ctiid.261988","name":"VDB-261988 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://vuldb.com/?submit.318988","name":"Submit #318988 | Tenda 4G300 V1.01.42 Buffer Overflow","tags":["third-party-advisory","x_transferred"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_42775C.md","tags":["related","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T20:33:52.514Z"}}]}}}