{"id":"CVE-2024-41171","state":"PUBLISHED","title":"A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions < V5.24), SINUMERIK 840D sl V4 (All versions), SINUMERIK ONE (All versions ","description":"A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions < V5.24), SINUMERIK 840D sl V4 (All versions), SINUMERIK ONE (All versions < V6.24). Affected devices do not properly enforce access restrictions to scripts that are regularly executed by the system with elevated privileges. This could allow an authenticated local attacker to escalate their privileges in the underlying system.","publishedAt":"2024-09-10T09:36:46.244Z","updatedAt":"2024-09-10T15:03:16.367Z","severity":{"score":9.3,"label":"Critical","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","source":"siemens"},"assigner":"siemens","products":["Siemens SINUMERIK 828D V4","Siemens SINUMERIK 828D V5","Siemens SINUMERIK 840D sl V4","Siemens SINUMERIK ONE"],"affected":[{"vendor":"Siemens","product":"SINUMERIK 828D V4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SINUMERIK 828D V5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.24","versionType":"custom"}]},{"vendor":"Siemens","product":"SINUMERIK 840D sl V4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SINUMERIK ONE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.24","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-342438.html"],"weaknesses":["CWE-732"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/41xxx/CVE-2024-41171.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-41171","state":"PUBLISHED","datePublished":"2024-09-10T09:36:46.244Z","dateUpdated":"2024-09-10T15:03:16.367Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-07-17T13:37:58.435Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions < V5.24), SINUMERIK 840D sl V4 (All versions), SINUMERIK ONE (All versions < V6.24). Affected devices do not properly enforce access restrictions to scripts that are regularly executed by the system with elevated privileges. This could allow an authenticated local attacker to escalate their privileges in the underlying system."}],"affected":[{"vendor":"Siemens","product":"SINUMERIK 828D V4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SINUMERIK 828D V5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.24","versionType":"custom"}]},{"vendor":"Siemens","product":"SINUMERIK 840D sl V4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SINUMERIK ONE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.24","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-342438.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":8.8,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","baseScore":9.3,"baseSeverity":"CRITICAL"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-732","lang":"en","description":"CWE-732: Incorrect Permission Assignment for Critical Resource","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-09-10T09:36:46.244Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"sinumerik_840d_sl_firmware","defaultStatus":"unknown","versions":[{"version":"4.0","status":"affected","lessThan":"*","versionType":"custom"}],"cpes":["cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*"]},{"vendor":"siemens","product":"sinumerik_one_firmware","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"6.24","versionType":"custom"}],"cpes":["cpe:2.3:o:siemens:sinumerik_one_firmware:*:*:*:*:*:*:*:*"]},{"vendor":"siemens","product":"sinumerik_828d_firmware","defaultStatus":"unknown","versions":[{"version":"4.0","status":"affected","lessThan":"5.24","versionType":"custom"}],"cpes":["cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-09-10T14:54:43.895216Z","id":"CVE-2024-41171","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-09-10T15:03:16.367Z"}}]}}}