{"id":"CVE-2024-4022","state":"PUBLISHED","title":"Keenetic KN-1010/KN-1410/KN-1711/KN-1810/KN-1910 Version Data version.js information disclosure","description":"A vulnerability was found in Keenetic KN-1010, KN-1410, KN-1711, KN-1810 and KN-1910 up to 4.1.2.15. It has been rated as problematic. Affected by this issue is some unknown functionality of the file /version.js of the component Version Data Handler. The manipulation leads to information disclosure. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261674 is the identifier assigned to this vulnerability. NOTE: The vendor is aware of this issue and plans to fix it by the end of 2024.","publishedAt":"2024-04-21T10:31:04.754Z","updatedAt":"2024-08-01T20:26:57.265Z","severity":{"score":5.3,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","source":"VulDB"},"assigner":"VulDB","products":["Keenetic KN-1010","Keenetic KN-1410","Keenetic KN-1711","Keenetic KN-1810","Keenetic KN-1910"],"affected":[{"vendor":"Keenetic","product":"KN-1010","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"modules":["Version Data Handler"]},{"vendor":"Keenetic","product":"KN-1410","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"modules":["Version Data Handler"]},{"vendor":"Keenetic","product":"KN-1711","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"modules":["Version Data Handler"]},{"vendor":"Keenetic","product":"KN-1810","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"modules":["Version Data Handler"]},{"vendor":"Keenetic","product":"KN-1910","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"modules":["Version Data Handler"]}],"references":["https://vuldb.com/?id.261674","https://vuldb.com/?ctiid.261674","https://vuldb.com/?submit.316276","https://netsecfish.notion.site/Information-Disclosure-in-Keenetic-Router-d4a12a499cef4acf80e191bdaf20c151?pvs=4"],"weaknesses":["CWE-200"],"ingestedAt":"2026-10-29T20:07:56.516Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/4xxx/CVE-2024-4022.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-4022","state":"PUBLISHED","datePublished":"2024-04-21T10:31:04.754Z","dateUpdated":"2024-08-01T20:26:57.265Z","assignerShortName":"VulDB","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateReserved":"2024-04-20T13:51:21.888Z"},"containers":{"cna":{"title":"Keenetic KN-1010/KN-1410/KN-1711/KN-1810/KN-1910 Version Data version.js information disclosure","descriptions":[{"lang":"en","value":"A vulnerability was found in Keenetic KN-1010, KN-1410, KN-1711, KN-1810 and KN-1910 up to 4.1.2.15. It has been rated as problematic. Affected by this issue is some unknown functionality of the file /version.js of the component Version Data Handler. The manipulation leads to information disclosure. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261674 is the identifier assigned to this vulnerability. NOTE: The vendor is aware of this issue and plans to fix it by the end of 2024."},{"lang":"de","value":"Eine problematische Schwachstelle wurde in Keenetic KN-1010, KN-1410, KN-1711, KN-1810 and KN-1910 bis 4.1.2.15 ausgemacht. Hierbei geht es um eine nicht exakt ausgemachte Funktion der Datei /version.js der Komponente Version Data Handler. Mittels Manipulieren mit unbekannten Daten kann eine information disclosure-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk. Der Exploit steht zur öffentlichen Verfügung."}],"affected":[{"vendor":"Keenetic","product":"KN-1010","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"modules":["Version Data Handler"]},{"vendor":"Keenetic","product":"KN-1410","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"modules":["Version Data Handler"]},{"vendor":"Keenetic","product":"KN-1711","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"modules":["Version Data Handler"]},{"vendor":"Keenetic","product":"KN-1810","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"modules":["Version Data Handler"]},{"vendor":"Keenetic","product":"KN-1910","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"modules":["Version Data Handler"]}],"references":[{"url":"https://vuldb.com/?id.261674","name":"VDB-261674 | Keenetic KN-1010/KN-1410/KN-1711/KN-1810/KN-1910 Version Data version.js information disclosure","tags":["vdb-entry"]},{"url":"https://vuldb.com/?ctiid.261674","name":"VDB-261674 | CTI Indicators (IOB, IOC, TTP, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.316276","name":"Submit #316276 | Keenetic Omni Router, Carrier Router, Viva Router, Ultra Router,  Ultra II Router,  Giga Router * 4.1.2.15/4.1.2.14/4.0.2.215/3.7.77/3.5.68/1.6.49 Information Disclosure","tags":["third-party-advisory"]},{"url":"https://netsecfish.notion.site/Information-Disclosure-in-Keenetic-Router-d4a12a499cef4acf80e191bdaf20c151?pvs=4","tags":["exploit"]}],"metrics":[{"cvssV3_1":{"version":"3.1","baseScore":5.3,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseSeverity":"MEDIUM"}},{"cvssV3_0":{"version":"3.0","baseScore":5.3,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseSeverity":"MEDIUM"}},{"cvssV2_0":{"version":"2.0","baseScore":5,"vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-200","type":"CWE","lang":"en","description":"CWE-200 Information Disclosure"}]}],"providerMetadata":{"shortName":"VulDB","orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateUpdated":"2024-04-22T12:38:32.107Z"},"timeline":[{"time":"2024-04-20T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-04-20T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-04-22T14:43:26.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"netsecfish (VulDB User)","type":"reporter"}]},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"keenetic","product":"kn_1010","defaultStatus":"unknown","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"cpes":["cpe:2.3:a:keenetic:kn_1010:1.6.49:*:*:*:*:*:*:*"]},{"vendor":"keenetic","product":"kn-1410","defaultStatus":"unknown","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"cpes":["cpe:2.3:a:keenetic:kn-1410:*:*:*:*:*:*:*:*"]},{"vendor":"keenetic","product":"kn-1711","defaultStatus":"unknown","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"cpes":["cpe:2.3:a:keenetic:kn-1711:*:*:*:*:*:*:*:*"]},{"vendor":"keenetic","product":"kn-1810","defaultStatus":"unknown","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"cpes":["cpe:2.3:a:keenetic:kn-1810:*:*:*:*:*:*:*:*"]},{"vendor":"keenetic","product":"kn-1910","defaultStatus":"unknown","versions":[{"version":"1.6.49","status":"affected"},{"version":"3.5.68","status":"affected"},{"version":"3.7.77","status":"affected"},{"version":"4.0.2.215","status":"affected"},{"version":"4.1.2.14","status":"affected"},{"version":"4.1.2.15","status":"affected"}],"cpes":["cpe:2.3:a:keenetic:kn-1910:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-05-20T17:21:24.240562Z","id":"CVE-2024-4022","options":[{"Exploitation":"poc"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-07-03T15:30:56.172Z"}},{"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.261674","name":"VDB-261674 | Keenetic KN-1010/KN-1410/KN-1711/KN-1810/KN-1910 Version Data version.js information disclosure","tags":["vdb-entry","x_transferred"]},{"url":"https://vuldb.com/?ctiid.261674","name":"VDB-261674 | CTI Indicators (IOB, IOC, TTP, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://vuldb.com/?submit.316276","name":"Submit #316276 | Keenetic Omni Router, Carrier Router, Viva Router, Ultra Router,  Ultra II Router,  Giga Router * 4.1.2.15/4.1.2.14/4.0.2.215/3.7.77/3.5.68/1.6.49 Information Disclosure","tags":["third-party-advisory","x_transferred"]},{"url":"https://netsecfish.notion.site/Information-Disclosure-in-Keenetic-Router-d4a12a499cef4acf80e191bdaf20c151?pvs=4","tags":["exploit","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T20:26:57.265Z"}}]}}}