{"id":"CVE-2024-39873","state":"PUBLISHED","title":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against u","description":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.","publishedAt":"2024-07-09T12:05:30.268Z","updatedAt":"2025-08-27T20:42:57.342Z","severity":{"score":8.7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens SINEMA Remote Connect Server"],"affected":[{"vendor":"Siemens","product":"SINEMA Remote Connect Server","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2 SP1","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-381581.html"],"weaknesses":["CWE-307"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/39xxx/CVE-2024-39873.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-39873","state":"PUBLISHED","datePublished":"2024-07-09T12:05:30.268Z","dateUpdated":"2025-08-27T20:42:57.342Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-07-01T13:05:40.288Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks."}],"affected":[{"vendor":"Siemens","product":"SINEMA Remote Connect Server","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2 SP1","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-381581.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C","baseScore":7.5,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","baseScore":8.7,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-307","lang":"en","description":"CWE-307: Improper Restriction of Excessive Authentication Attempts","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-07-09T12:05:30.268Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"sinema_remote_connect_server","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"3.2_sp1","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:sinema_remote_connect_server:-:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-39873","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-07-09T13:18:38.543900Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-08-27T20:42:57.342Z"}},{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-381581.html","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T04:33:10.241Z"}}]}}}