{"id":"CVE-2024-39868","state":"PUBLISHED","title":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain ","description":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges.","publishedAt":"2024-07-09T12:05:23.810Z","updatedAt":"2025-08-27T20:42:56.576Z","severity":{"score":7.2,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens SINEMA Remote Connect Server"],"affected":[{"vendor":"Siemens","product":"SINEMA Remote Connect Server","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2 SP1","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-381581.html"],"weaknesses":["CWE-425"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/39xxx/CVE-2024-39868.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-39868","state":"PUBLISHED","datePublished":"2024-07-09T12:05:23.810Z","dateUpdated":"2025-08-27T20:42:56.576Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-07-01T13:05:40.287Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges."}],"affected":[{"vendor":"Siemens","product":"SINEMA Remote Connect Server","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2 SP1","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-381581.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C","baseScore":7.6,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N","baseScore":7.2,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-425","lang":"en","description":"CWE-425: Direct Request ('Forced Browsing')","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-07-09T12:05:23.810Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"sinema_remote_connect_server","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2 SP1","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-39868","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-07-10T19:43:18.767680Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-08-27T20:42:56.576Z"}},{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-381581.html","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T04:33:10.311Z"}}]}}}