{"id":"CVE-2024-3980","state":"PUBLISHED","title":"The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names","description":"The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names\nthat are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or\nother files that are critical to the application.","publishedAt":"2024-08-27T12:42:41.124Z","updatedAt":"2025-08-27T21:24:22.839Z","severity":{"score":9.9,"label":"Critical","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","source":"Hitachi Energy"},"assigner":"Hitachi Energy","products":["Hitachi Energy MicroSCADA X SYS600","Hitachi Energy MicroSCADA Pro SYS600"],"affected":[{"vendor":"Hitachi Energy","product":"MicroSCADA X SYS600","defaultStatus":"unaffected","versions":[{"version":"10.0","status":"affected","lessThanOrEqual":"10.5","versionType":"custom"}]},{"vendor":"Hitachi Energy","product":"MicroSCADA Pro SYS600","defaultStatus":"unaffected","versions":[{"version":"9.4 FP2 HF1","status":"affected","lessThanOrEqual":"9.4 FP2 HF5","versionType":"custom"},{"version":"9.4 FP1","status":"affected","versionType":"custom"}]}],"references":["https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160&LanguageCode=en&DocumentPartId=&Action=Launch"],"weaknesses":["CWE-22"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/3xxx/CVE-2024-3980.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-3980","state":"PUBLISHED","datePublished":"2024-08-27T12:42:41.124Z","dateUpdated":"2025-08-27T21:24:22.839Z","assignerShortName":"Hitachi Energy","assignerOrgId":"e383dce4-0c27-4495-91c4-0db157728d17","dateReserved":"2024-04-19T12:45:24.793Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names\nthat are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or\nother files that are critical to the application."}],"affected":[{"vendor":"Hitachi Energy","product":"MicroSCADA X SYS600","defaultStatus":"unaffected","versions":[{"version":"10.0","status":"affected","lessThanOrEqual":"10.5","versionType":"custom"}]},{"vendor":"Hitachi Energy","product":"MicroSCADA Pro SYS600","defaultStatus":"unaffected","versions":[{"version":"9.4 FP2 HF1","status":"affected","lessThanOrEqual":"9.4 FP2 HF5","versionType":"custom"},{"version":"9.4 FP1","status":"affected","versionType":"custom"}]}],"references":[{"url":"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160&LanguageCode=en&DocumentPartId=&Action=Launch"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.9,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"MicroSCADA X SYS600"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"MicroSCADA Pro SYS600"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-22","description":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Hitachi Energy","orgId":"e383dce4-0c27-4495-91c4-0db157728d17","dateUpdated":"2024-10-29T13:35:30.374Z"},"impacts":[{"capecId":"CAPEC-38","descriptions":[{"lang":"en","value":"CAPEC-38 Leveraging/Manipulating Configuration File Search Paths"}]}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"hitachienergy","product":"microscada_sys600","defaultStatus":"unknown","versions":[{"version":"10.0","status":"affected","lessThanOrEqual":"10.5","versionType":"custom"}],"cpes":["cpe:2.3:a:hitachienergy:microscada_sys600:10.0:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-28T14:10:05.924302Z","id":"CVE-2024-3980","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-08-27T21:24:22.839Z"}}]}}}