{"id":"CVE-2024-3909","state":"PUBLISHED","title":"Tenda AC500 execCommand formexeCommand stack-based overflow","description":"A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","publishedAt":"2024-04-17T11:31:05.865Z","updatedAt":"2024-08-01T20:26:57.136Z","severity":{"score":8.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"VulDB"},"assigner":"VulDB","products":["Tenda AC500"],"affected":[{"vendor":"Tenda","product":"AC500","versions":[{"version":"2.0.1.9(1307)","status":"affected"}]}],"references":["https://vuldb.com/?id.261145","https://vuldb.com/?ctiid.261145","https://vuldb.com/?submit.313804","https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md"],"weaknesses":["CWE-121"],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/3xxx/CVE-2024-3909.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-3909","state":"PUBLISHED","datePublished":"2024-04-17T11:31:05.865Z","dateUpdated":"2024-08-01T20:26:57.136Z","assignerShortName":"VulDB","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateReserved":"2024-04-17T05:42:53.219Z"},"containers":{"cna":{"title":"Tenda AC500 execCommand formexeCommand stack-based overflow","descriptions":[{"lang":"en","value":"A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"In Tenda AC500 2.0.1.9(1307) wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion formexeCommand der Datei /goform/execCommand. Mittels dem Manipulieren des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"affected":[{"vendor":"Tenda","product":"AC500","versions":[{"version":"2.0.1.9(1307)","status":"affected"}]}],"references":[{"url":"https://vuldb.com/?id.261145","name":"VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.261145","name":"VDB-261145 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.313804","name":"Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow","tags":["third-party-advisory"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md","tags":["exploit"]}],"metrics":[{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","type":"CWE","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"providerMetadata":{"shortName":"VulDB","orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateUpdated":"2024-04-17T11:31:05.865Z"},"timeline":[{"time":"2024-04-17T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-04-17T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-04-17T07:53:08.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_tu (VulDB User)","type":"reporter"}]},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"tenda","product":"ac500_firmware","defaultStatus":"unknown","versions":[{"version":"2.0.1.9\\(1307\\)","status":"affected"}],"cpes":["cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-3909","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-04-22T15:10:58.576153Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-06-04T17:31:11.551Z"}},{"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.261145","name":"VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow","tags":["vdb-entry","technical-description","x_transferred"]},{"url":"https://vuldb.com/?ctiid.261145","name":"VDB-261145 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://vuldb.com/?submit.313804","name":"Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow","tags":["third-party-advisory","x_transferred"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md","tags":["exploit","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T20:26:57.136Z"}}]}}}