{"id":"CVE-2024-3596","state":"PUBLISHED","title":"RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.","description":"RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.","publishedAt":"2024-07-09T12:02:53.001Z","updatedAt":"2026-10-15T00:25:35.013Z","severity":{"score":9,"label":"Critical","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","source":"CISA-ADP"},"assigner":"certcc","products":["IETF RFC"],"affected":[{"vendor":"IETF","product":"RFC","versions":[{"version":"2865","status":"affected"}]}],"references":["https://datatracker.ietf.org/doc/html/rfc2865","https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/","https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf","https://www.blastradius.fail/","http://www.openwall.com/lists/oss-security/2024/07/09/4","https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014","https://cert-portal.siemens.com/productcert/html/ssa-794185.html","https://cert-portal.siemens.com/productcert/html/ssa-723487.html","https://security.netapp.com/advisory/ntap-20240822-0001/","https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol","https://www.kb.cert.org/vuls/id/456537","https://cert-portal.siemens.com/productcert/html/ssa-364175.html","https://cert-portal.siemens.com/productcert/html/ssa-770770.html"],"weaknesses":[],"ingestedAt":"2026-10-29T20:07:39.287Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/3xxx/CVE-2024-3596.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2024-3596","state":"PUBLISHED","datePublished":"2024-07-09T12:02:53.001Z","dateUpdated":"2026-10-15T00:25:35.013Z","assignerShortName":"certcc","assignerOrgId":"37e5125f-f79b-445b-8fad-9564f167944b","dateReserved":"2024-04-10T15:09:45.391Z"},"containers":{"cna":{"title":"RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.","descriptions":[{"lang":"en","value":"RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature."}],"affected":[{"vendor":"IETF","product":"RFC","versions":[{"version":"2865","status":"affected"}]}],"references":[{"url":"https://datatracker.ietf.org/doc/html/rfc2865"},{"url":"https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"},{"url":"https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"},{"url":"https://www.blastradius.fail/"},{"url":"http://www.openwall.com/lists/oss-security/2024/07/09/4"},{"url":"https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-794185.html","name":"Siemens Security Advisory by Siemens ProductCERT for  SIPROTEC, SICAM and related product","tags":["vendor-advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-723487.html","name":"Siemens Security Advisory by Siemens ProductCERT to SCALANCE, RUGGEDCOM and related products.","tags":["vendor-advisory"]}],"problemTypes":[{"descriptions":[{"lang":"en","description":"CWE-328: Use of Weak Hash"}]},{"descriptions":[{"lang":"en","description":"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor"}]},{"descriptions":[{"lang":"en","description":"CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel"}]}],"providerMetadata":{"shortName":"certcc","orgId":"37e5125f-f79b-445b-8fad-9564f167944b","dateUpdated":"2025-09-03T17:29:16.788Z"},"source":{"discovery":"EXTERNAL"},"credits":[{"lang":"en","type":"finder","value":"Thanks to Sharon Goldberg, Miro Haller, Nadia Heninger, Mike Milano, Dan Shumow, Marc Stevens, and Adam Suhl who researched and reported this vulnerability"}],"x_generator":{"engine":"VINCE 3.0.4","env":"prod","origin":"https://cveawg.mitre.org/api/cve/CVE-2024-3596"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"ietf","product":"rfc","defaultStatus":"unknown","versions":[{"version":"2865","status":"affected"}],"cpes":["cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:*"]}],"metrics":[{"cvssV3_1":{"scope":"CHANGED","version":"3.1","baseScore":9,"attackVector":"NETWORK","baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"HIGH","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"HIGH"}},{"other":{"type":"ssvc","content":{"timestamp":"2024-07-11T03:55:37.141738Z","id":"CVE-2024-3596","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-09-04T21:05:25.373Z"}},{"title":"CVE Program Container","references":[{"url":"https://security.netapp.com/advisory/ntap-20240822-0001/"},{"url":"https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol"},{"url":"https://datatracker.ietf.org/doc/html/rfc2865","tags":["x_transferred"]},{"url":"https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/","tags":["x_transferred"]},{"url":"https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf","tags":["x_transferred"]},{"url":"https://www.blastradius.fail/","tags":["x_transferred"]},{"url":"http://www.openwall.com/lists/oss-security/2024/07/09/4","tags":["x_transferred"]},{"url":"https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014","tags":["x_transferred"]},{"url":"https://www.kb.cert.org/vuls/id/456537"}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2025-11-04T17:20:52.225Z"}},{"affected":[{"vendor":"Siemens","product":"CPC80 Central Processing/Communication","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V16.51","versionType":"custom"}]},{"vendor":"Siemens","product":"CPCI85 Central Processing/Communication","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.20","versionType":"custom"}]},{"vendor":"Siemens","product":"POWER METER SICAM Q100 family","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.70","versionType":"custom"}]},{"vendor":"Siemens","product":"POWER METER SICAM Q200 family","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.83","versionType":"custom"}]},{"vendor":"Siemens","product":"Powerlink IP","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.23","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM APE1808","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM APE1808","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SICAM AK 3","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SICAM BC","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SICAM GridEdge (Classic)","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SICAM GridEdge Applications for SICAM 8 Platform","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SICAM GridPass","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.50","versionType":"custom"}]},{"vendor":"Siemens","product":"SICAM TM","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SICORE Base system","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.20.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 - CP200 Devices","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD84 (CP300)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD89 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD89 (CP300) V9.6x","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V9.68","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 6MU85 (CP300)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7KE85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SA82 (CP100)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V8.90","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SA82 (CP150)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SA86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SA87 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SD82 (CP100)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V8.90","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SD82 (CP150)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SD86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SD87 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SJ81 (CP100)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V8.90","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SJ81 (CP150)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SJ82 (CP100)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V8.90","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SJ82 (CP150)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SJ85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SJ86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SK82 (CP100)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V8.90","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SK82 (CP150)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SK85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SL82 (CP100)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V8.90","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SL82 (CP150)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SL86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SL87 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SS85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7ST85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7ST85 (CP300) V9.6x","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V9.68","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7ST86 (CP300)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7ST86 (CP300) V9.8x","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V9.83","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SX82 (CP150)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SX85 (CP300)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SY82 (CP150)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7UM85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7UT82 (CP100)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V8.90","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7UT82 (CP150)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7UT85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7UT86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7UT87 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7VE85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7VK87 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7VU85 (CP300)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 Compact 7SX800 (CP050)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM CROSSBOW","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.6","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM i800","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM i800NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM i801","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM i801NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM i802","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM i802NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM i803","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM i803NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM M2100","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM M2100NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM M2200","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM M2200NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM M969","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM M969NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RM1224 LTE(4G) EU","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RM1224 LTE(4G) NAM","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RMC30","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RMC30NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RMC8388 V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RMC8388 V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RMC8388NC V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RMC8388NC V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX MX5000","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX MX5000RE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1400","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1500","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1501","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1510","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1511","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1512","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1524","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1536","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX5000","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.17.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RP110","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RP110NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS1600","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS1600F","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS1600FNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS1600NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS1600T","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS1600TNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS400","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS400NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS401","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS401NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416NCv2 V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416NCv2 V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416P","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416PNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416PNCv2 V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416PNCv2 V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416Pv2 V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416Pv2 V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416v2 V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS416v2 V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS8000","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS8000A","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS8000ANC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS8000H","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS8000HNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS8000NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS8000T","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS8000TNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900 (32M) V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900 (32M) V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900G","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900G (32M) V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900G (32M) V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900GNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900GNC(32M) V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900GNC(32M) V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900GP","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900GPNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900L","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900LNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900M-GETS-C01","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900M-GETS-XX","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900M-STND-C01","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900M-STND-XX","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900MNC-GETS-C01","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900MNC-GETS-XX","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900MNC-STND-XX","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900MNC-STND-XX-C01","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900NC(32M) V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900NC(32M) V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS900W","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS910","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS910L","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS910LNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS910NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS910W","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS920L","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS920LNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS920W","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS930L","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS930LNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS930W","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS940G","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS940GNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS969","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RS969NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100 (32M) V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100 (32M) V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100NC(32M) V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100NC(32M) V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100P","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100P (32M) V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100P (32M) V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100PNC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100PNC (32M) V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100PNC (32M) V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2200","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2200NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2288 V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2288 V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2288NC V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2288NC V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300 V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300 V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300NC V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300NC V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300P V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300P V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300PNC V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300PNC V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2488 V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2488 V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2488NC V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG2488NC V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG907R","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG908C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG909R","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG910C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG920P V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG920P V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG920PNC V4.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.3.11","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSG920PNC V5.X","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSL910","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RSL910NC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RST2228","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RST2228P","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RST2428P","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RST916C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM RST916P","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.10.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M804PB","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M812-1 ADSL-Router","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M812-1 ADSL-Router","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M816-1 ADSL-Router","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M816-1 ADSL-Router","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M826-2 SHDSL-Router","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M874-2","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M874-3","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M874-3 3G-Router (CN)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M876-3","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M876-3 (ROK)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M876-4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M876-4 (EU)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE M876-4 (NAM)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE MUM853-1 (A1)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE MUM853-1 (B1)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE MUM853-1 (EU)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (A1)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (B1)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (CN)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (EU)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (RoW)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE S615 EEC LAN-Router","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE S615 LAN-Router","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE SC622-2C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE SC626-2C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE SC632-2C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE SC636-2C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE SC642-2C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE SC646-2C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W1748-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W1748-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W1788-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W1788-2 EEC M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W1788-2 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W1788-2IA M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W721-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W721-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W722-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W722-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W722-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W734-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W734-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W734-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W734-1 RJ45 (USA)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W738-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W738-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W748-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W748-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W748-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W748-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W761-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W761-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W774-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W774-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W774-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W774-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W774-1 RJ45 (USA)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W778-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W778-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC (USA)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W786-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W786-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W786-2 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W786-2 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W786-2 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W786-2 SFP","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W786-2 SFP","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-1 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-1 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-2 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-2 M12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-2 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-2 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE W788-2 RJ45","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.6.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WAB762-1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WAM763-1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WAM763-1 (ME)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WAM763-1 (US)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WAM766-1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WAM766-1 (ME)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WAM766-1 (US)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC (ME)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC (US)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WUB762-1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WUB762-1 iFeatures","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WUM763-1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WUM763-1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WUM763-1 (US)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WUM763-1 (US)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WUM766-1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WUM766-1 (ME)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE WUM766-1 (USA)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0.0","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (230V, coated)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (230V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (24V, coated)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (24V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 230V, coated)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 230V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 24V, coated)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 24V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X304-2FE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X306-1LD FE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (230V, coated)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (230V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (24V, coated)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (24V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 230V, coated)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 230V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 24V, coated)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 24V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-3","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-3","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-3LD","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X307-3LD","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2LD","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2LD","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2LH","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2LH","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2LH+","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2LH+","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2M","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2M","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2M PoE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2M PoE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2M TS","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X308-2M TS","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X310","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X310","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X310FE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X310FE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X320-1 FE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X320-1-2LD FE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE X408-2","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB205-3 (SC, PN)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB205-3 (ST, E/IP)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB205-3 (ST, E/IP)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB205-3 (ST, PN)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB205-3LD (SC, E/IP)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB205-3LD (SC, PN)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB206-2 (SC)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB206-2 (ST/BFOC)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB206-2 LD","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB206-2 SC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB206-2 ST","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB206-2LD","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB208 (E/IP)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB208 (PN)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB213-3 (SC, E/IP)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB213-3 (SC, PN)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB213-3 (ST, E/IP)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB213-3 (ST, PN)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB213-3LD (SC, E/IP)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB213-3LD (SC, PN)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB216 (E/IP)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XB216 (PN)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC206-2 (SC)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC206-2 (ST/BFOC)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC206-2G PoE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC206-2G PoE (54 V DC)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC206-2G PoE EEC (54 V DC)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC206-2SFP","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC206-2SFP EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC206-2SFP G","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC206-2SFP G (EIP DEF.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC206-2SFP G EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC208","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC208EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC208G","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC208G (EIP def.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC208G EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC208G PoE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC208G PoE (54 V DC)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC216","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC216-3G PoE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC216-3G PoE (54 V DC)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC216-4C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC216-4C G","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC216-4C G (EIP Def.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC216-4C G EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC216EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC224","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC224-4C G","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC224-4C G (EIP Def.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC224-4C G EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC316-8","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC324-4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC324-4 EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC332","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC416-8","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC424-4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XC432","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XCH328","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XCM324","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XCM328","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XCM332","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XF204","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XF204 DNA","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XF204-2BA","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XF204-2BA DNA","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XF204G","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XM408-4C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XM408-4C (L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XM408-8C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XM408-8C (L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XM416-4C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XM416-4C (L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208 (Ethernet/IP)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208G","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208G EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208G PoE EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208G PP","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208PoE EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP208PoE EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP216","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP216 (Ethernet/IP)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP216 (V2)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP216EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP216EEC (V2)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP216G","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP216G EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP216G PoE EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP216POE EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XP216PoE EEC (V2)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR302-32","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR302-32","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR302-32","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR322-12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR322-12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR322-12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-12M TS (24V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-12M TS (24V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (230V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (230V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (230V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (230V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (24V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (24V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (24V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE (24V, ports on rear)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE TS (24V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324-4M PoE TS (24V, ports on front)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324WG (24 x FE, AC 230V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR324WG (24 X FE, DC 24V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR326-2C PoE WG","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR326-2C PoE WG (without UL)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR326-8","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR326-8","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR326-8","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR326-8 EEC","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR328-4C WG (28xGE, AC 230V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR328-4C WG (28xGE, DC 24V)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR502-32","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR502-32","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR502-32","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR522-12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR522-12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR522-12","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR524-8C, 1x230V","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR524-8C, 1x230V (L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR524-8C, 24V","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR524-8C, 24V (L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR524-8C, 2x230V","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR524-8C, 2x230V (L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR524-8WG","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR524-8WG","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR524-8WG","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR524-8WG","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR526-8","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR526-8","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR526-8","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.3","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR526-8C, 1x230V","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR526-8C, 1x230V (L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR526-8C, 24V","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR526-8C, 24V (L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR526-8C, 2x230V","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR526-8C, 2x230V (L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR528-6M","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR528-6M (2HR2, L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR528-6M (2HR2)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR528-6M (L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR552-12M","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR552-12M (2HR2, L3 int.)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR552-12M (2HR2)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XR552-12M (2HR2)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRH334 (24 V DC, 8xFO, CC)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 12xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 8xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 12xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 8xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (2x230 V AC, 12xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (2x230 V AC, 8xFO)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.2","versionType":"custom"}]},{"vendor":"Siemens","product":"SINEC INS","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.0 SP2 Update 4","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS NET SCALANCE X308-2","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.1.9","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS NET SCALANCE XC206-2","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS NET SCALANCE XC206-2SFP","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS NET SCALANCE XC208","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS NET SCALANCE XC216-4C","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V4.6","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-364175.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-723487.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-770770.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-794185.html"}],"providerMetadata":{"shortName":"siemens-SADP","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","dateUpdated":"2026-10-15T00:25:35.013Z"},"x_adpType":"supplier"}]}}}