{"id":"CVE-2024-35783","state":"PUBLISHED","title":"A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All ","description":"A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.","publishedAt":"2024-09-10T09:36:32.225Z","updatedAt":"2025-01-14T10:30:01.253Z","severity":{"score":9.4,"label":"Critical","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","source":"siemens"},"assigner":"siemens","products":["Siemens SIMATIC BATCH V9.1","Siemens SIMATIC Information Server 2020","Siemens SIMATIC Information Server 2022","Siemens SIMATIC PCS 7 V9.1","Siemens SIMATIC Process Historian 2020","Siemens SIMATIC Process Historian 2022","Siemens SIMATIC WinCC Runtime Professional V18","Siemens SIMATIC WinCC Runtime Professional V19","Siemens SIMATIC WinCC V7.4","Siemens SIMATIC WinCC V7.5","Siemens SIMATIC WinCC V8.0"],"affected":[{"vendor":"Siemens","product":"SIMATIC BATCH V9.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC Information Server 2020","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2020 SP2 Update 5","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC Information Server 2022","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2022 SP1 Update 2","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC PCS 7 V9.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V9.1 SP2 UC06","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC Process Historian 2020","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2020 SP2 Update 5","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC Process Historian 2022","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2022 SP1 Update 2","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Professional V18","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V18 Update 5","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Professional V19","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V19 Update 3","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V7.4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V7.5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V7.5 SP2 Update 18","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V8.0","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.0 Update 5","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-629254.html"],"weaknesses":["CWE-250"],"ingestedAt":"2026-10-29T20:07:30.303Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/35xxx/CVE-2024-35783.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-35783","state":"PUBLISHED","datePublished":"2024-09-10T09:36:32.225Z","dateUpdated":"2025-01-14T10:30:01.253Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-05-17T11:07:53.264Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges."}],"affected":[{"vendor":"Siemens","product":"SIMATIC BATCH V9.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC Information Server 2020","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2020 SP2 Update 5","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC Information Server 2022","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2022 SP1 Update 2","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC PCS 7 V9.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V9.1 SP2 UC06","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC Process Historian 2020","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2020 SP2 Update 5","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC Process Historian 2022","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2022 SP1 Update 2","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Professional V18","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V18 Update 5","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Professional V19","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V19 Update 3","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V7.4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V7.5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V7.5 SP2 Update 18","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V8.0","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V8.0 Update 5","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-629254.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":9.1,"baseSeverity":"CRITICAL"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","baseScore":9.4,"baseSeverity":"CRITICAL"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-250","lang":"en","description":"CWE-250: Execution with Unnecessary Privileges","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2025-01-14T10:30:01.253Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"simatic_batch","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:simatic_wincc_runtime_professional:18:*:*:*:*:*:*:*","cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:*","cpe:2.3:h:siemens:simatic_process_historian:2020:-:*:*:*:*:*:*","cpe:2.3:a:siemens:simatic_process_historian:2022:*:*:*:*:*:*:*","cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:*","cpe:2.3:a:siemens:simatic_information_server:2020:-:*:*:*:*:*:*","cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*","cpe:2.3:a:siemens:simatic_batch:9.1:-:*:*:*:*:*:*"]},{"vendor":"siemens","product":"simatic_wincc","defaultStatus":"unknown","versions":[{"version":"7.4","status":"affected","lessThan":"7.5_sp2_update_18","versionType":"custom"},{"version":"8.0","status":"affected","lessThan":"8.0_update_5","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-09-10T15:12:46.700884Z","id":"CVE-2024-35783","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-09-10T17:31:08.389Z"}}]}}}