{"id":"CVE-2024-35293","state":"PUBLISHED","title":"Schneider Elektronik Series 700 prone to missing authentication for critical reset function","description":"An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.","publishedAt":"2024-10-02T09:51:01.799Z","updatedAt":"2024-10-02T14:48:19.675Z","severity":{"score":9.1,"label":"Critical","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","source":"CERTVDE"},"assigner":"CERTVDE","products":["Schneider Elektronik Series 700"],"affected":[{"vendor":"Schneider Elektronik","product":"Series 700","defaultStatus":"unaffected","versions":[{"version":"0.0.0.0","status":"affected","lessThanOrEqual":"0.1.17.6","versionType":"custom"}]}],"references":["https://www.schneider-elektronik.de/wp-content/uploads/2024/07/SAR-202405-1.pdf"],"weaknesses":["CWE-306"],"ingestedAt":"2026-10-29T20:07:30.303Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/35xxx/CVE-2024-35293.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-35293","state":"PUBLISHED","datePublished":"2024-10-02T09:51:01.799Z","dateUpdated":"2024-10-02T14:48:19.675Z","assignerShortName":"CERTVDE","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateReserved":"2024-05-15T12:37:05.393Z"},"containers":{"cna":{"title":"Schneider Elektronik Series 700 prone to missing authentication for critical reset function","descriptions":[{"lang":"en","value":"An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS."}],"affected":[{"vendor":"Schneider Elektronik","product":"Series 700","defaultStatus":"unaffected","versions":[{"version":"0.0.0.0","status":"affected","lessThanOrEqual":"0.1.17.6","versionType":"custom"}]}],"references":[{"url":"https://www.schneider-elektronik.de/wp-content/uploads/2024/07/SAR-202405-1.pdf","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.1,"baseSeverity":"CRITICAL","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306: Missing Authentication for Critical Function","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"CERTVDE","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateUpdated":"2024-10-02T09:51:01.799Z"},"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Felix Eberstaller and David Schauer from Limes Security"}],"source":{"discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-02T14:46:56.834735Z","id":"CVE-2024-35293","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-10-02T14:48:19.675Z"}}]}}}