{"id":"CVE-2024-35206","state":"PUBLISHED","title":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected application does not expire the session. This could allow an ","description":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected application does not expire the session. This could allow an attacker to get unauthorized access.","publishedAt":"2024-06-11T11:15:46.277Z","updatedAt":"2025-02-11T10:28:37.047Z","severity":{"score":8.5,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens SINEC Traffic Analyzer"],"affected":[{"vendor":"Siemens","product":"SINEC Traffic Analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.2","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-196737.html"],"weaknesses":["CWE-613"],"ingestedAt":"2026-10-29T20:07:30.303Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/35xxx/CVE-2024-35206.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-35206","state":"PUBLISHED","datePublished":"2024-06-11T11:15:46.277Z","dateUpdated":"2025-02-11T10:28:37.047Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-05-13T17:54:10.655Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected application does not expire the session. This could allow an attacker to get unauthorized access."}],"affected":[{"vendor":"Siemens","product":"SINEC Traffic Analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V1.2","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-196737.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","baseScore":7.7,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N","baseScore":8.5,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-613","lang":"en","description":"CWE-613: Insufficient Session Expiration","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2025-02-11T10:28:37.047Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"sinec_traffic_analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"1.2","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:sinec_traffic_analyzer:0:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-06-11T13:18:02.698244Z","id":"CVE-2024-35206","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-06-11T13:20:58.878Z"}},{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-196737.html","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T03:07:46.875Z"}}]}}}