{"id":"CVE-2024-32753","state":"PUBLISHED","title":"TYCO Illustra Pro Gen 4 - JQuery version","description":"Under certain circumstances the camera may be susceptible to known vulnerabilities associated with the JQuery versions prior to 3.5.0 third-party component","publishedAt":"2024-07-11T15:30:39.367Z","updatedAt":"2024-08-16T14:50:34.077Z","severity":{"score":7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N","source":"jci"},"assigner":"jci","products":["Johnson Controls TYCO Illustra Pro4 Fixed cameras","Johnson Controls TYCO Illustra Pro4 PTZ cameras","Johnson Controls TYCO Illustra Flex4 Fixed & PTZ cameras","Johnson Controls TYCO Illustra Pro4 MultiSensor Cameras","Johnson Controls TYCO Illustra Flex4 DualSensor Cameras"],"affected":[{"vendor":"Johnson Controls","product":"TYCO Illustra Pro4 Fixed cameras","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS016.05.03.01.0007","versionType":"custom"}]},{"vendor":"Johnson Controls","product":"TYCO Illustra Pro4 PTZ cameras","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS010.24.03.00.0005","versionType":"custom"}]},{"vendor":"Johnson Controls","product":"TYCO Illustra Flex4 Fixed & PTZ cameras","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS018.24.03.00.0010","versionType":"custom"}]},{"vendor":"Johnson Controls","product":"TYCO Illustra Pro4 MultiSensor Cameras","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS017.24.03.00.0009","versionType":"custom"}]},{"vendor":"Johnson Controls","product":"TYCO Illustra Flex4 DualSensor Cameras","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS022.24.03.00.0008","versionType":"custom"}]}],"references":["https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories","https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-03"],"weaknesses":["CWE-1395"],"ingestedAt":"2026-10-29T20:07:21.467Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/32xxx/CVE-2024-32753.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-32753","state":"PUBLISHED","datePublished":"2024-07-11T15:30:39.367Z","dateUpdated":"2024-08-16T14:50:34.077Z","assignerShortName":"jci","assignerOrgId":"7281d04a-a537-43df-bfb4-fa4110af9d01","dateReserved":"2024-04-17T17:26:35.180Z"},"containers":{"cna":{"title":"TYCO Illustra Pro Gen 4 - JQuery version","descriptions":[{"lang":"en","value":"Under certain circumstances the camera may be susceptible to known vulnerabilities associated with the JQuery versions prior to 3.5.0 third-party component"}],"affected":[{"vendor":"Johnson Controls","product":"TYCO Illustra Pro4 Fixed cameras","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS016.05.03.01.0007","versionType":"custom"}]},{"vendor":"Johnson Controls","product":"TYCO Illustra Pro4 PTZ cameras","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS010.24.03.00.0005","versionType":"custom"}]},{"vendor":"Johnson Controls","product":"TYCO Illustra Flex4 Fixed & PTZ cameras","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS018.24.03.00.0010","versionType":"custom"}]},{"vendor":"Johnson Controls","product":"TYCO Illustra Pro4 MultiSensor Cameras","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS017.24.03.00.0009","versionType":"custom"}]},{"vendor":"Johnson Controls","product":"TYCO Illustra Flex4 DualSensor Cameras","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS022.24.03.00.0008","versionType":"custom"}]}],"references":[{"url":"https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-03"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"NETWORK","baseScore":7,"baseSeverity":"HIGH","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"LOW","userInteraction":"ACTIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"LOW","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1395","description":"CWE-1395: Dependency on Vulnerable Third-Party Component","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"jci","orgId":"7281d04a-a537-43df-bfb4-fa4110af9d01","dateUpdated":"2024-08-16T14:50:34.077Z"},"datePublic":"2024-07-09T16:00:00.000Z","impacts":[{"capecId":"CAPEC-588","descriptions":[{"lang":"en","value":"CAPEC-588: DOM-Based XSS"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<ul><li><p>Update firmware of <strong>Pro4 Fixed</strong> cameras to <strong>Illustra.SS016.24.03.00.0007</strong></p></li><li><p>Update firmware of <strong>Pro4 PTZ</strong> cameras to<strong> Illustra.SS010.24.03.00.0005</strong></p></li><li><p>Update firmware of <strong>Flex4 Fixed &amp; PTZ</strong> cameras to <strong>Illustra.SS018.24.03.00.0010</strong></p></li><li><p>Update firmware of <strong>Pro4 MultiSensor </strong>cameras to <strong>Illustra.SS017.24.03.00.0009</strong></p></li><li><p>Update firmware of <strong>Flex4 DualSensor </strong>cameras to <strong>Illustra.SS022.24.03.00.0008</strong></p></li></ul>\n\n<br>"}],"value":"*  Update firmware of Pro4 Fixed cameras to Illustra.SS016.24.03.00.0007\n\n\n  *  Update firmware of Pro4 PTZ cameras to Illustra.SS010.24.03.00.0005\n\n\n  *  Update firmware of Flex4 Fixed & PTZ cameras to Illustra.SS018.24.03.00.0010\n\n\n  *  Update firmware of Pro4 MultiSensor cameras to Illustra.SS017.24.03.00.0009\n\n\n  *  Update firmware of Flex4 DualSensor cameras to Illustra.SS022.24.03.00.0008"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"johnsoncontrols","product":"illustra_flex4_dualsensor_firmware","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS022.24.03.00.0008","versionType":"custom"}],"cpes":["cpe:2.3:o:johnsoncontrols:illustra_flex4_dualsensor_firmware:*:*:*:*:*:*:*:*"]},{"vendor":"johnsoncontrols","product":"illustra_pro4_multisensor_firmware","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS017.24.03.00.0009","versionType":"custom"}],"cpes":["cpe:2.3:o:johnsoncontrols:illustra_pro4_multisensor_firmware:*:*:*:*:*:*:*:*"]},{"vendor":"johnsoncontrols","product":"illustra_flex4_fixed_firmware","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS018.24.03.00.0010","versionType":"custom"}],"cpes":["cpe:2.3:o:johnsoncontrols:illustra_flex4_fixed_firmware:*:*:*:*:*:*:*:*"]},{"vendor":"johnsoncontrols","product":"illustra_flex4_ptz_firmware","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS018.24.03.00.0010","versionType":"custom"}],"cpes":["cpe:2.3:o:johnsoncontrols:illustra_flex4_ptz_firmware:*:*:*:*:*:*:*:*"]},{"vendor":"johnsoncontrols","product":"illustra_pro4_ptz_firmware","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS010.24.03.00.0005","versionType":"custom"}],"cpes":["cpe:2.3:o:johnsoncontrols:illustra_pro4_ptz_firmware:*:*:*:*:*:*:*:*"]},{"vendor":"johnsoncontrols","product":"illustra_pro_gen_4_firmware","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"Illustra.SS016.05.03.01.0007","versionType":"custom"}],"cpes":["cpe:2.3:o:johnsoncontrols:illustra_pro_gen_4_firmware:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-12T19:41:41.470969Z","id":"CVE-2024-32753","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-07-17T14:23:41.965Z"}},{"title":"CVE Program Container","references":[{"url":"https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories","tags":["x_transferred"]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-03","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T02:20:35.268Z"}}]}}}