{"id":"CVE-2024-32292","state":"PUBLISHED","title":"Tenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.","description":"Tenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.","publishedAt":"2024-04-17T00:00:00.000Z","updatedAt":"2024-08-02T02:06:44.049Z","severity":{"score":8.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"CISA-ADP"},"assigner":"mitre","products":["n/a n/a"],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":["https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formexecommand_cmdi.md"],"weaknesses":["CWE-77"],"ingestedAt":"2026-10-29T20:07:21.467Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/32xxx/CVE-2024-32292.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-32292","state":"PUBLISHED","datePublished":"2024-04-17T00:00:00.000Z","dateUpdated":"2024-08-02T02:06:44.049Z","assignerShortName":"mitre","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","dateReserved":"2024-04-12T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Tenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formexecommand_cmdi.md"}],"problemTypes":[{"descriptions":[{"type":"text","lang":"en","description":"n/a"}]}],"providerMetadata":{"shortName":"mitre","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","dateUpdated":"2024-04-17T13:57:39.171Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"tenda","product":"w30e_firmware","defaultStatus":"unknown","versions":[{"version":"1.0.1.25\\(633\\)","status":"affected"}],"cpes":["cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*"]}],"metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":8.8,"attackVector":"ADJACENT_NETWORK","baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"HIGH"}},{"other":{"type":"ssvc","content":{"id":"CVE-2024-32292","role":"CISA Coordinator","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2024-04-22T19:54:55.618800Z"}}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-77","lang":"en","type":"CWE","description":"CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')"}]}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-06-04T17:50:33.615Z"}},{"title":"CVE Program Container","references":[{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formexecommand_cmdi.md","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T02:06:44.049Z"}}]}}}