{"id":"CVE-2024-31980","state":"PUBLISHED","title":"A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.256), Parasolid V36.0 (All versions < V36.0.210), Parasolid V36.1 (All versions < V36.1.185). The affec","description":"A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.256), Parasolid V36.0 (All versions < V36.0.210), Parasolid V36.1 (All versions < V36.1.185). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T part file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-23468)","publishedAt":"2024-05-14T10:02:27.405Z","updatedAt":"2024-08-02T01:59:50.660Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","source":"siemens"},"assigner":"siemens","products":["Siemens Parasolid V35.1","Siemens Parasolid V36.0","Siemens Parasolid V36.1"],"affected":[{"vendor":"Siemens","product":"Parasolid V35.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V35.1.256","versionType":"custom"}]},{"vendor":"Siemens","product":"Parasolid V36.0","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V36.0.210","versionType":"custom"}]},{"vendor":"Siemens","product":"Parasolid V36.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V36.1.185","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-489698.html"],"weaknesses":["CWE-787"],"ingestedAt":"2026-10-29T20:07:21.467Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/31xxx/CVE-2024-31980.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-31980","state":"PUBLISHED","datePublished":"2024-05-14T10:02:27.405Z","dateUpdated":"2024-08-02T01:59:50.660Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-04-08T12:20:23.712Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.256), Parasolid V36.0 (All versions < V36.0.210), Parasolid V36.1 (All versions < V36.1.185). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T part file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-23468)"}],"affected":[{"vendor":"Siemens","product":"Parasolid V35.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V35.1.256","versionType":"custom"}]},{"vendor":"Siemens","product":"Parasolid V36.0","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V36.0.210","versionType":"custom"}]},{"vendor":"Siemens","product":"Parasolid V36.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V36.1.185","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-489698.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","lang":"en","description":"CWE-787: Out-of-bounds Write","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-05-15T07:24:15.740Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"parasolid","defaultStatus":"unknown","versions":[{"version":"35.1","status":"affected","lessThan":"35.1.256","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"]},{"vendor":"siemens","product":"parasolid","defaultStatus":"unknown","versions":[{"version":"36.0","status":"affected","lessThan":"36.0.210","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"]},{"vendor":"siemens","product":"parasolid","defaultStatus":"unknown","versions":[{"version":"36.1","status":"affected","lessThan":"36.1.185","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-05-14T13:39:14.173926Z","id":"CVE-2024-31980","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-06-06T17:09:32.754Z"}},{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-489698.html","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T01:59:50.660Z"}}]}}}