{"id":"CVE-2024-2763","state":"PUBLISHED","title":"Tenda AC10U setcfm formSetCfm stack-based overflow","description":"A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","publishedAt":"2024-03-21T20:31:03.792Z","updatedAt":"2024-08-01T19:25:41.329Z","severity":{"score":8.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"VulDB"},"assigner":"VulDB","products":["Tenda AC10U"],"affected":[{"vendor":"Tenda","product":"AC10U","versions":[{"version":"15.03.06.48","status":"affected"}]}],"references":["https://vuldb.com/?id.257600","https://vuldb.com/?ctiid.257600","https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md"],"weaknesses":["CWE-121"],"ingestedAt":"2026-10-29T20:07:21.467Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/2xxx/CVE-2024-2763.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-2763","state":"PUBLISHED","datePublished":"2024-03-21T20:31:03.792Z","dateUpdated":"2024-08-01T19:25:41.329Z","assignerShortName":"VulDB","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateReserved":"2024-03-21T15:17:45.636Z"},"containers":{"cna":{"title":"Tenda AC10U setcfm formSetCfm stack-based overflow","descriptions":[{"lang":"en","value":"A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.48 entdeckt. Davon betroffen ist die Funktion formSetCfm der Datei goform/setcfm. Mit der Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"affected":[{"vendor":"Tenda","product":"AC10U","versions":[{"version":"15.03.06.48","status":"affected"}]}],"references":[{"url":"https://vuldb.com/?id.257600","name":"VDB-257600 | Tenda AC10U setcfm formSetCfm stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.257600","name":"VDB-257600 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md","tags":["exploit"]}],"metrics":[{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","type":"CWE","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"providerMetadata":{"shortName":"VulDB","orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateUpdated":"2024-03-21T20:31:03.792Z"},"timeline":[{"time":"2024-03-21T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-03-21T01:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-03-21T16:22:54.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_miemie (VulDB User)","type":"reporter"}]},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-2763","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-03-22T17:49:42.492927Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-07-05T17:21:16.064Z"}},{"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.257600","name":"VDB-257600 | Tenda AC10U setcfm formSetCfm stack-based overflow","tags":["vdb-entry","technical-description","x_transferred"]},{"url":"https://vuldb.com/?ctiid.257600","name":"VDB-257600 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md","tags":["exploit","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T19:25:41.329Z"}}]}}}