{"id":"CVE-2024-25955","state":"PUBLISHED","title":"Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution ","description":"Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.","publishedAt":"2024-03-28T19:05:10.021Z","updatedAt":"2024-08-01T23:52:06.240Z","severity":{"score":7.2,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","source":"dell"},"assigner":"dell","products":["Dell Virtual Appliance (vApp) Manager"],"affected":[{"vendor":"Dell","product":"Virtual Appliance (vApp) Manager","defaultStatus":"unaffected","versions":[{"version":"N/A","status":"affected","lessThan":"9.2.4.9","versionType":"semver"},{"version":"N/A","status":"affected","lessThan":"9.2.4.6","versionType":"semver"},{"version":"N/A","status":"affected","lessThan":"5978","versionType":"semver"}]}],"references":["https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"],"weaknesses":["CWE-78"],"ingestedAt":"2026-10-29T20:07:10.607Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/25xxx/CVE-2024-25955.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-25955","state":"PUBLISHED","datePublished":"2024-03-28T19:05:10.021Z","dateUpdated":"2024-08-01T23:52:06.240Z","assignerShortName":"dell","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateReserved":"2024-02-13T05:32:19.480Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."}],"affected":[{"vendor":"Dell","product":"Virtual Appliance (vApp) Manager","defaultStatus":"unaffected","versions":[{"version":"N/A","status":"affected","lessThan":"9.2.4.9","versionType":"semver"},{"version":"N/A","status":"affected","lessThan":"9.2.4.6","versionType":"semver"},{"version":"N/A","status":"affected","lessThan":"5978","versionType":"semver"}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"dell","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateUpdated":"2024-03-28T19:05:10.021Z"},"credits":[{"lang":"en","type":"finder","value":"Dell Technologies would like to thank 33a6099 for reporting these issues.  "}],"datePublic":"2024-03-28T06:30:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"dell","product":"unisphere_for_powermax_virtual_appliance","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"9.2.4.9","versionType":"custom"}],"cpes":["cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:-:*:*:*:*:*:*:*"]},{"vendor":"dell","product":"solutions_enabler_virtual_appliance","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"9.2.4.6","versionType":"custom"}],"cpes":["cpe:2.3:a:dell:solutions_enabler_virtual_appliance:-:*:*:*:*:*:*:*"]},{"vendor":"dell","product":"unisphere_for_powermax","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"5978","versionType":"custom"}],"cpes":["cpe:2.3:a:dell:unisphere_for_powermax:-:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-04-08T17:44:26.390852Z","id":"CVE-2024-25955","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-06-20T18:39:13.355Z"}},{"title":"CVE Program Container","references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities","tags":["vendor-advisory","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T23:52:06.240Z"}}]}}}