{"id":"CVE-2024-24923","state":"PUBLISHED","title":"A vulnerability has been identified in Simcenter Femap (All versions < V2401.0000), Simcenter Femap (All versions < V2306.0001). The affected applications contain an out of bounds ","description":"A vulnerability has been identified in Simcenter Femap (All versions < V2401.0000), Simcenter Femap (All versions < V2306.0001). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted Catia MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22055)","publishedAt":"2024-02-13T09:00:31.872Z","updatedAt":"2025-05-09T18:29:47.332Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens Simcenter Femap"],"affected":[{"vendor":"Siemens","product":"Simcenter Femap","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2401.0000","versionType":"custom"}]},{"vendor":"Siemens","product":"Simcenter Femap","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2306.0001","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-000072.html"],"weaknesses":["CWE-125"],"ingestedAt":"2026-10-29T20:07:10.607Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/24xxx/CVE-2024-24923.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-24923","state":"PUBLISHED","datePublished":"2024-02-13T09:00:31.872Z","dateUpdated":"2025-05-09T18:29:47.332Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-02-01T15:21:44.578Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Simcenter Femap (All versions < V2401.0000), Simcenter Femap (All versions < V2306.0001). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted Catia MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22055)"}],"affected":[{"vendor":"Siemens","product":"Simcenter Femap","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2401.0000","versionType":"custom"}]},{"vendor":"Siemens","product":"Simcenter Femap","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2306.0001","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-000072.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-125","lang":"en","description":"CWE-125: Out-of-bounds Read","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-03-12T10:22:07.551Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-000072.html","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T23:36:21.460Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-02-13T14:54:00.777463Z","id":"CVE-2024-24923","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-05-09T18:29:47.332Z"}}]}}}